WARNING
BEFORE OPERATING THIS Fireplace, CARE-
FULLY READ THE FOLLOWING.
1. Verify the gas line service does not exceed 10.5 in. w.c.
and is not below 5.0 in. w.c. for natural gas, nor exceeds
13.0 in. w.c. or is below 11.0 in. w.c. for LP gas.
2. Check and inspect the fireplace for gas leaks. In the event
of gas leaks, cut off the gas supply to the fireplace immedi-
ately and call your gas supplier. Verify the gas line has been
purged.
3. Verify that all exhaust and inlet air pipes are unobstructed and
properly joined.
4. Visually verify the burners are free of dust and debris.
See Figures 56 and 67.
5. Check and verify that logs are place correctly. See pages
33 to 35. The logs must be in the correct position or the fire-
place will not operate correctly.
DO NOT light fireplace without the logs installed, the fireplace
will not operate properly.
6. Verify that all panels are secured in place and that the glass
assembly door has been locked in position.
7. Verify the two burner switches are in the OFF position before
applying power and the main power switch.
8. After verifying and checking all the above points, proceed to
lighting instructions. Refer to Page 38.
9. Verify that the polarity of the connections are correct and the
line voltage power leads are secure.
Note: If using a surround, verify it is installed per the instruc-
tions included with the kit.