Wiring; Start Up Check List - Empire Comfort Systems FG28BMK(N,P)-1 Installation Instructions Manual

Mantis power-vent high-efficiency fireplace
Table of Contents

Advertisement

Available languages

Available languages

WARNING
Potential risk of fire, electric shock, and personal injury.
Take precautions to reduce such risks.
CAUTION
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.
WARNING
BEFORE OPERATING THIS APPLIANCE,
CAREFULLY READ THE FOLLOWING.
31793-3-1015

WIRING

Figure 37

START UP CHECK LIST

This appliance is equipped with a three-prong [grounding]
plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong recep-
tacle. Do not cut or remove the grounding prong from this
plug. For an ungrounded receptacle, an adapter, which has two
prongs and a wire for grounding, can be purchased.
Proper line voltage polarity must be maintained in order for the
control system to operate correctly. Verify the incoming neutral line
is connected to the white wire and the incoming "hot" line is con-
nected to the black wire. The fireplace will not operate properly
unless the polarity and ground are correct.
1.
Verify the gas line service does not exceed 10.5 in. w.c.
and is not below 5.0 in. w.c. for natural gas, nor exceeds
13.0 in. w.c. or is below 11.0 in. w.c. for LP gas.
2.
Check and inspect the appliance for gas leaks. In the event
of gas leaks, cut off the gas supply to the fireplace immedi-
ately and call your gas supplier. Verify the gas line has been
purged.
3.
Verify that all exhaust and inlet air pipes are unobstructed and
properly joined.
4.
Visually verify the burner is free of dust and debris.
5.
Verify that all panels are secured in place and that the glass
assembly door has been locked in position.
6.
Verify that the polarity of the connections are correct and the
line voltage power leads are secure.
7.
After verifying and checking all the above points, proceed to
lighting instructions. Refer to Page 24.
Note: Verify the surround is installed per the instructions in-
cluded with the kit.