Error messages

If an error or fault occurs in the course of the program this is indicated on the display.
N.B.
To reset the error message the main switch
T h e d i s p l a y
Description
shows
Over flow
Means that the condensation tank is full. If the con-
densation is pumped directly out via the drain hose,
check that there are no kinks or blockages in the hose.
Maximum program time
Thermistor fault
Heat protection (not provided on all machines)
Sensor fault
must be turned off.
Explanation / proposed measure
Drain the condensation tank and restart. If the error
message reappears this may mean that the lower
water reservoir is full because the pump or hoses are
blocked or worn.
When the machine has run for the maximum time (3
hours), the machine stops. Check and replace any
fuses that have blown in the house distribution box. To
quit the error message switch off the machine or open
the door. If this does not help call service.
The machine indicates whether there is an interrup-
tion in supply or short-circuit in the thermistor.
A thermostat in the rear section has indicated that the
heat has risen, which indicates that too much fluff is
building up in the filter and condensation package.
Clean the filter and condensor
Fault in the moisture sensor. The moisture value is
unreasonable, <0V or > 6V for 300 seconds. This
error message may also appear if you are drying
clothing that is already dry or if the machine is empty.
Open the door and the message will disappear.