Follett MCC400A Installation, Operation And Service Manual page 27

220v 60hz/230v 50hz ice machines
Table of Contents

Advertisement

Normal operation – Stage 6
When the dwell time of 20 minutes has expired, the B-T LED goes off. The ice machine goes through the normal start-
up sequence when the bin level control signals the control board for ice. The WTR LED will remain on as long as the
water sensor in the fl oat reservoir senses water.
GRN IN
ELEC BOX
GREEN/YELLOW
BROWN
BLUE
START
CAPACITOR
RUN
CAP.
ORANGE
BLACK
FAN
WHITE
WHITE
Diagnostic sequence – Stage 7
The 20 minute error LED (20M) is on, indicating that the control board has sensed an over-torque condition (above
2.5 AMPS on the gearmotor). The 20M LED remains on for 20 minutes after an over-torque condition has occurred.
The ice machine remains off as long as the 20M LED is on. When the 20M LED goes off, the control board will try to
go through a normal start-up sequence. The WTR LED remains on as long as the water sensor in the fl oat reservoir
senses water.
GRN IN
ELEC BOX
GREEN/YELLOW
BROWN
BLUE
START
CAPACITOR
RUN
CAP.
ORANGE
BLACK
FAN
WHITE
WHITE
WATER
SENSOR
WHITE
BLACK
WHITE
POTENTIAL
START RELAY
BLACK
ORANGE
COMPRESSOR
4
2
BLACK
START
RUN
YELLOW
3
GEARMOTOR
WATER
SENSOR
WHITE
BLACK
WHITE
POTENTIAL
START RELAY
BLACK
ORANGE
COMPRESSOR
4
2
BLACK
START
RUN
YELLOW
3
GEARMOTOR
RED
COMP
FAN
DRV
RED
BLACK
RED
COMP
FAN
DRV
RED
BLACK
27
POWER
BIN SIGNAL
COMPRESSOR
SWITCH
HIGH PRESSURE
SAFETY SWITCH
BLACK
BLACK
POWER
BIN SIGNAL
COMPRESSOR
SWITCH
HIGH PRESSURE
SAFETY SWITCH
BLACK
BLACK
DISPENSER
BIN
T-STAT
SWITCH
DISPENSER
BIN
T-STAT
SWITCH

Hide quick links: