ATC Control
When ATC cold wash is selected,
Heater turns on if the water temperature in the tub is below 60 degrees F. Heater turns off if
the water temperature is above 70 degrees F or the time runs out for wash time. The cycle
time will not be extended to reach the desired temperature.
When ATC warm wash is selected, Heater turns on if the water temperature in the tub is
below 95 degrees F. Heater will turn off if the water temperature is above 105 degrees F or the
time runs out for wash tumble. The cycle time will not be extended to reach the desired
temperature.
When hot wash is selected, Heater will turn on if the water temperature in the tub is below
120 degrees F. Heater turns off if the water temperature is above 130 degrees F. or the time
runs out for wash tumble. The cycle time will not be extended to reach the desired
temperature.
When the Sanitary Cycle is selected, Heater turns on if the water temperature in the tub is
below 141 degrees F. Heater turns off if the water temperature is above 151 degrees F. The
wash cycle will be extended to achieve the temperature of 151 degrees F.
Note: The heater will not turn on more than once in a wash cycle (no reheating).
MAH9700 Spin Speeds
1200 RPM
1000 RPM
800 RPM
600 RPM
400 RPM
0 RPM