Maintaining Your Fireplace's Appearance

Fingerprints or other marks left on the optional plated surface may become etched in place if they are not wiped clean
prior to turning the fireplace on. Clean the plated surface with denatured alcohol and a soft cloth (with the fireplace
cool). Other cleaners may leave a film that may become etched into the surface.

Accent Light Replacement

The accent lights in your fireplace provide additional lighting. The bulbs will burn out over time. To replace, follow
the directions below:
Shut off gas to the fireplace and let it cool for 15 minutes.
Remove the glass (see page 18) and media.
Replace the halogen bulbs with the following bulbs:
(NOTE: .Take care to not touch the bulbs with your fingers – use foam packing or paper towel to hold the bulb):
35 Watt 120 Volt T4 Halogen Bulb (G6.35 Base)

Yearly Service Procedure

Failure to inspect and maintain the fireplace may lead to improper combustion and a potentially dangerous
situation. We recommend the following procedures be done by a qualified technician.
1.
Turn the pilot flame to continuous. It should touch approximately 3/8" of the top of the flame sensor. If it does
not, contact your dealer for service.
2.
Shut off gas to the fireplace and let it cool for 15 minutes. Remove the glass (see page 18).
3.
Remove the logs (NOTE: the logs are very fragile). If severely deteriorated, replace. Check the logs for
sooting. A small amount of soot along the bottom of the logs is normal. If excessive sooting is found, the
fireplace will require adjustment. Contact your dealer.
4.
Inspect the burner and remove any debris.
Make sure the burner is not warped, cracked, or damaged.
Check the firebox and area around the pilot to make sure there is no warping or damage.
If any problem is found, discontinue use and contact your dealer for service.
5.
Replace the logs. Clean and replace the glass (see
replace. Make sure the gasket along the perimeter of the glass contacts the face of the firebox and forms an air-
tight seal. If it does not, re-align or replace the gasket to insure an air-tight seal.
6.
Inspect the area behind the access door. Clean if necessary. Check the gas
control valve and the gas lines. If damage is found, discontinue use and contact
your dealer for service. Clean the air channels, ducts, and blower (if applicable).
7.
Start the main burner. Inspect the main burner and pilot flame. After 15 minutes
the flames should be orange/yellow and not touch the top of the firebox. If the
pilot or main burners do not burn correctly, contact your dealer for service.
Monitor blower operation.
8.
Remove any debris or vegetation near the vent termination. Contact your dealer
if any sooting or deterioration is found near the vent termination. Venting system
should be examined by a qualified agency.