Remote Set-Up

Verify the Switch is on "REMOTE"

The battery holder has a switch built into it (see Figure 1). This switch must remain in the REMOTE
position for the remote to operate.

Synchronize the Transmitter to the IFC

The transmitter will need to be synchronized to the IFC (Integrated Fireplace Control) before the remote
will work correctly. Synchronizing is done in the following two steps below (see Figure 2):
1. Press the PRG (Program) button on the battery box (IFC will beep 3 times).
2. Press the "ON" button on the transmitter (IFC will beep 3 times).
NOTE: If power is cut off to the IFC for an extended period of time, you may need to re-synchronize the
remote.

Clearing the System Memory

This appliance uses an Integrated Fireplace Control (IFC) to store the unique code for the
remote control. If you wish to clear the system memory, MAKE SURE GAS IS TURNED OFF
TO THE APPLIANCE then press the PRG (Program) button for 10 seconds. The pilot will start
to spark repeatedly, signifying all system memory has been cleared. The system will return to its
original configuration: a remote will need to be synchronized; and, the system will operate under
continuous pilot mode.