Installation; Installing Countertop Dispensers Without Legs - Follett Symphony 12CI400A Installation, Operation And Service Manual

Ice and water dispensers 12 series
Table of Contents

Advertisement

Installation

Before you begin
All dispensers must be installed level in both directions to ensure proper operation.
Service and ventilation clearances: 6" (153mm) on right side of dispenser, 6" (153mm) at top for ventilation and
12" (305mm) at top recommended for service.
Countertop units installed without legs provide the option of taking utilities out bottom or back of dispenser (on
wall mount units and countertop units with legs, utilities exit from back). See counter cutout drawings for bottom
exiting utilities on units with and without drain pans. For installations where utilities exit through back of dispenser,
refer to back view drawings.
Wall mount models without drain pan are designed for use above sinks.
Counter depth must allow front of sink to be a minimum of 23.5 (597mm) from wall.

Installing countertop dispensers without legs

1. Position dispenser in desired
location, mark dispenser outline
on counter and remove dispenser.
2. Regardless of whether utilities will
exist through back or bottom of
dispenser, drill four (4) 7/16" holes
in counter to anchor dispenser to
counter (Fig. 1).
3. For utilities existing through
bottom only:
(a)
Make cut out as shown in
Fig. 1.
(b)
Move plug from drain T to
back of unit (Fig. 2).
4. For all units: Apply a thick bead
approximately 1/4" (6mm)
diameter of NSF listed silicone
sealant (Dow Corning RTV-732 or
equivalent) 1/4" (6mm) inside
marked outline of dispenser.
5. Carefully lower dispenser on
counter in proper position and
secure to counter with four (4)
3/8"-16NC bolts.
6. Smooth excess sealant around
outside of dispenser.
Fig. 1 – Counter information
16"
(407mm)
437" (12mm)
diameter
5
14.4"
(366mm)
12"
(305mm)
2" (51mm)
cutout for
connections
through bottom
0.8"
(21mm)
1.5"
(39mm)
1" (26mm)
12"
(305mm)
15.9"
(404mm)
18"
(458mm)
4"
(102mm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Symphony 12hi400a

Table of Contents