T T o o p p V V e e n n t t & & F F a a n n A A s s s s e e m m b b l l y y
The top vent and fan assembly is located in the
top right rear corner of the tub. This vent is
normally closed, opening in only the dry cycle by
the electronic control. The vent is monitored by the
control throughout the cycle to insure it stays
closed. The vent and fan motor is replaced only
as an assembly.
The blower operates with 12VDC with a speed of
3500rpm. This assembly plugs directly into the
electronic control. If the control senses a failure in
the blower or the vent baffle it will stop the
dishwasher and show a failure code.
To remove the top vent and fan assembly:
1. Pull unit from its installation position.
2. Disconnect the electrical leads from wire
harness on exterior of unit.
2. Remove the top wire rack.
3. Reach inside tub, turn retaining nut clockwise
until retaining nut falls from the top vent
assembly. (See Figure 5-30)
W W a a t t e e r r V V a a l l v v e e R R e e m m o o v v a a l l
The water valve mounts to the front left side of the
control assembly and is accessed by removing the
kickplate. The water valve is wired directly to the
electronic control and operates on 120VAC. All
cycle fills on this dishwasher are time fills, which
are regulated by a flow restrictor in the valve body.
The flow rate of this valve is .83gpm with the
incoming water pressure from between 20 to
120psi.
To remove the water valve:
1. Remove kickplate.
2. Make sure household water supply is turned
off. Disconnect the water supply line from the
front of the water valve. Have a towel under
the water valve to absorb water leaking out of
the supply line and unit.
3. Using a #20 Torx bit, extract the screw
securing the small access cover to the valve
mounting bracket.
4. Using a #20 Torx bit, extract the two screws
securing the valve mounting bracket to the unit
frame. (See Figure 5-31)
5. Pull water valve forward to remove wires from
solenoid.The solenoid resistance is 1000ohms.
6. Using a pliers, remove tubing clamp from
water line exiting valve.
C C o o m m p p o o n n e e n n t t T T e e a a r r d d o o w w n n
Top Vent and
Fan Assembly
Retaining
Nut
F F i i g g u u r r e e 5 5 - - 3 3 0 0 . . T T o o p p V V e e n n t t & & F F a a n n A A s s s s e e m m b b l l y y
Small Access
Screws
F F i i g g u u r r e e 5 5 - - 3 3 1 1 . . W W a a t t e e r r V V a a l l v v e e R R e e m m o o v v a a l l