Gas-fired high efficiency two stage variable upflow/horizontal furnaces

Advertisement

TECHNICAL GUIDE
AFFINITY
MODELS: PV8
GAS-FIRED
HIGH EFFICIENCY TWO STAGE VARIABLE
UPFLOW/HORIZONTAL FURNACES
STANDARD & LoNOx
80% AFUE
NATURAL GAS
80 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
This product was manufactured
in a plant whose quality system
is certified/registered as being
in conformity with ISO 9001.
DESCRIPTION
These high efficiency, compact units employ induced com-
bustion, reliable hot surface ignition and high heat transfer
aluminized tubular heat exchangers. The units are factory
shipped for installation in upflow or horizontal applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage
and are also ideal for commercial applications. All units are
factory assembled, wired and tested to assure safe depend-
able and economical installation and operation.
These units are Category I listed and may be common
vented with another gas appliance as allowed by the
National Fuel Gas Code.
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applica-
tions.
5-year limited parts warranty.
FEATURES
• Two stage heating operation includes:
- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation
• Provides increased comfort level & very quiet unit opera-
tion
• Field Selectable delay timer allows two stage operation w/
single stage thermostat
• Acoustically insulated blower compartment for reduced
blower sound level
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
tion.
• Integrated control module for reliable, economical opera-
tion.
• High velocity filter and side -return filter rack provided for
easy field installation.
• Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
• Induced combustion system with inshot main burners for
quiet, efficient operation.
• 100% shut off main gas valve for extra safety.
• Variable Speed ECM with large, quiet blower.
• ClimaTrak Technology allows dealer to customize comfort
settings based on regional location.
• 24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
• Hi-tech tubular aluminized steel primary heat exchanger.
• Timed on, adjustable off blower capability for maximum
comfort.
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance
or service.
• Insulated blower compartment for quiet operation.
• Independent door removal for greater durability and ease
of access.
• LoNOx models have been designed to meet specific code
requirements.
• LoNOx models may not be converted to propane.
036-21606-001 Rev. A (0804)

Advertisement

Table of Contents
loading

Summary of Contents for York PV8

  • Page 1 • Independent door removal for greater durability and ease of access. Visit us on the web at www.york.com for the most • LoNOx models have been designed to meet specific code up-to-date technical information.
  • Page 2: Cabinet And Duct Dimensions

    036-21606-001 Rev. A (0804) (VENT CONNECTIONS) POWER WIRING 7/8” HOLE 14-3/4 13-3/4 5-3/8 2-1/2 32-1/2 GAS INLET ACCESS 1-1/4 x 2-1/2 WIRING 7/8” K.O. 23-1/2 2-1/4 8-3/4 1-1/8 30-1/8 FRONT RIGHT SIDE LEFT SIDE T’STAT WIRING 7/8” K.O. 1-3/8 1-1/4 26-3/4 4”...
  • Page 3: Ratings & Physical / Electrical Data

    036-21606-001 Rev. A (0804) RATINGS & PHYSICAL / ELECTRICAL DATA High Fire Input Output Cabinet Low Fire Airflow AFUE Air Temp. MODEL BTU/H BTU/H Width Air Temp. Rise Rise High/Low High/Low °F °F PV8A12(N,L)080UH11 80/59 64/48 1200 14 1/2 80.0 40-70 40-70 PV8B16(N,L)100UH11...
  • Page 4: Air Flow Data

    036-21606-001 Rev. A (0804) AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM INPUT High Fire: 60,000 / Low Fire: 39,000 INPUT High Fire: 80,000 / Low Fire: 52,000 JUMPER SETTINGS High High COOL Tap ADJ Tap 1340 1675 1155...
  • Page 5: Filter Performance - Pressure Drop Inches W.c

    036-21606-001 Rev. A (0804) FILTER PERFORMANCE NOTE: The filter pressure drop values in the “Filter Perfor- mance” table shown below are typical values for the type of The airflow capacity data published in the “Blower Perfor- filter listed and should only be used as a guideline. Actual mance”...
  • Page 6: High Altitude Pressure Switches

    036-21606-001 Rev. A (0804) ACCESSORIES EXTERNAL BOTTOM RETURN FILTER RACK W/FILTER - Provides a cleanable, high velocity type filter and filter rack. PROPANE (LP) CONVERSION KIT - Attaches to the bottom of the furnace. 1NP0480 - All units 1BR0314 - For 14-1/2” cabinets This accessory conversion kit may be used to convert natural 1BR0317 - For 17-1/2"...
  • Page 7 036-21606-001 Rev. A (0804) NOTES Unitary Products Group...
  • Page 8 NOTES Subject to change without notice. Printed in U.S.A. 036-21606-001 Rev. A (0804) Copyright © by York International Corp. 2004. All rights reserved. Supersedes:Nothing Unitary 5005 Norman Products York Group Drive 73069...

Table of Contents