Panasonic S-36PU1E5A Technical Data & Service Manual page 166

R410a models
Hide thumbs Also See for S-36PU1E5A:
Table of Contents

Advertisement

1
Single-Type
1-1. Unit Specifications
PEY1
3. Wall Mounted Type S-60PK1E5A / U-60PEY1E5
INDOOR
PANEL
OUTDOOR
Branch pipe
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
CURRENT
INPUT POWER
C
ANNUAL CONSUMPTION TOTAL kWh
O
EER/EER CLASS
O
Pdsign
L
Erp
SEER
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
NOISE OUTDOOR
CAPACITY
CURRENT
INPUT POWER
H
COP/COP CLASS
E
Pdsign
A
Tbivalen
T
Erp
SCOP
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
NOISE OUTDOOR
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
I/D AIR
FLOW
HEAT
O/D AIR
COOL
FLOW
HEAT
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Condition
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
ADD GAS AMOUNT g/m (oz/ft)
N
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1 In case it is necessary to indicate the air flow volume in (l/s), the value in (m
*2 If the EUROVENT Certified models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3 Network Impedance shall be applicable for EUROPE and CHINA models.
*4 The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5 EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6 SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
MODEL
S-60PK1E5A
MODEL
MODEL
MODEL
ø, Hz
1ø 50Hz
V
220
kW
6.0
BTU/h
20500
A
0.59
W
57
TOTAL W
4
TOTAL(W/W) 5/("A"~"G")
-
kW
-
(W/W)
-
kWh
-
-
%
-
dB-A (H/M/L)
47/44/40
Power Level dB
64/59/54
dB-A (H/L)
Power Level dB
kW
6.0
BTU/h
20500
A
0.59
W
57
TOTAL W
TOTAL(W/W) 5/("A"~"G")
-
kW
-
°C
-
(W/W)
-
kWh
-
-
%
-
dB-A (H/M/L)
47/44/40
Power Level dB
64/59/54
dB-A (H/L)
Power Level dB
0.59/57
0.58/57
-
L/h(Pt/h)
3.4
Pa
3
3
m
/min (ft
/min)
18/14.5/11.5 (636/512/406)
3
3
m
/min (ft
/min)
18/14.5/11.5 (636/512/406)
3
3
m
/min (ft
/min)
3
3
m
/min (ft
/min)
300 (11-1/32)
1065 (41-15/16)
230 (9-1/32)
14.5 (32)
15 (16)
Cool (DBT)
18°C ~ 32°C
Heat (DBT)
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
flared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
ISO5151 / EN14511 / EN14825 / EN12102
230
240
220
6.0
6.0
20500
20500
0.58
0.52
8.80
57
57
1.800k
-
1.860k
-
930
-
-
3.23
-
-
-
-
-
-
-
-
-
-
-
-
-
-
93
6.0
6.0
20500
20500
0.58
0.52
7.05
57
57
1.440k
-
1.500k
-
-
4.00
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
93
-
-
-
0.52/57
18/3.680k
-
-
8.80/1.8k
-
47
(7.1)
-
30
35
R410A
310
1140
380
18 (40)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
5 ~ 50
(16.4 ~ 164)
40
(0.430)
20
(65.6)
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
3
1-156
-
U-60PEY1E5
-
1ø 50Hz
230
240
8.50
8.25
1.800k
1.800k
1.860k
1.860k
930
930
3.23 / A
3.23
6.0
-
5.4
-
389
-
A
-
92
91
46/-
65/-
6.80
6.60
1.440k
1.440k
1.500k
1.500k
4.00 / A
4.00
6.0
-
-6
-
3.9
-
2154
-
A
-
92
91
-
-
50/-
69/-
18/3.810k
18/3.930k
8.50/1.8k
8.25/1.8k
-
90
-
(1067)
(1229)
1.70k
(60.0)
569 (22-13/32)
790 (31-7/64)
285 (11-7/32)
645
921
386
42 (93)
46 (101)
4 (5)
-10°C ~ 43°C
-15°C ~ 24°C
flared type, 5.0(16.4)
(49.2/98.4)
Min
Max
2.0
7.0
6800
23900
-
-
-
-
325
2.750k
-
-
6.15
2.55
-
-
1.8
7.0
6100
23900
-
-
-
-
275
2.200k
6.55
3.18
-
-
/
/
/
/
/
/
/
/
/
~
~