Miller PipePro 304 Owner's Manual page 43

Engine driven welding generator
Table of Contents

Advertisement

C. Engine
Trouble
Engine will not crank.
Engine cranks, but does not start.
Engine starts, but stops when Engine
Control switch returns to Run position.
Engine does not stop.
Engine stopped during normal
operation.
Battery discharges between uses.
Reset circuit breaker CB8 (see Section 8-9).
Check battery voltage.
Check battery connections and tighten if necessary.
Have Factory Authorized Service Agent check Engine Control switch S2.
Check fuel level (see Section 5-2).
Open fuel valve (see Section 5-2).
Check oil level (see Section 5-2). Engine will not start if oil pressure is low.
Reset circuit breaker CB10 (see Section 8-9).
Check coolant level and fan belt (see Section 5-2 and engine manual). Engine will not start if coolant
temperature is high.
Use Glow Plug switch if unit does not start in cold weather. If unit still does not start, reset circuit
breaker CB7 (see Section 8-9).
Service primary and secondary fuel filters (see Section 8-5).
Check battery and replace if necessary.
Check engine charging system according to engine manual.
Bleed air from fuel system according to engine manual.
Reset customer-supplied emergency air shutdown valve (if equipped) (see Section 5-9).
Have Factory Authorized Service Agent check low oil pressure switch S5, engine coolant tempera-
ture switch S4, and control relay CR1.
See engine manual.
Check oil level (see Section 5-2). Engine will not start if oil pressure is too low.
Check coolant level and fan belt (see Section 5-2 and engine manual). Engine will not start if engine
temperature is too high.
Check and refill crankcase with proper viscosity oil for operating temperature, if necessary (see en-
gine manual).
Have Factory Authorized Service Agent check low oil pressure switch S5, engine coolant tempera-
ture switch S4, Engine Control switch S2, control relay CR1, and voltage regulator board PC8.
Stop engine by pushing down engine stop lever (see Section 5-2) or closing fuel valve (see Section
5-2). After stopping engine, adjust fuel solenoid linkage (see engine manual).
Check fuel level (see Section 5-2).
Open fuel valve (see Section 5-2).
Check oil level (see Section 5-2). Engine stops if oil pressure is too low.
Check coolant level and fan belt (see Section 5-2 and engine manual). Engine stops if engine temper-
ature is too high.
Bleed air from fuel system according to engine manual.
Have Factory Authorized Service Agent check low oil pressure switch S5 and engine coolant temper-
ature switch S4.
Clean top of battery with baking soda and water solution; rinse with clear water.
Periodically recharge battery (approximately every 3 months).
Replace battery.
Check voltage regulator according to engine manual.
Return To Table Of Contents
Remedy
OM-492 Page 39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents