5-7. Selecting Weld Cable Sizes*

Weld Output
Terminals
Y Turn off power before
connecting to weld out-
put terminals.
Y Do not use worn, dam-
aged, undersized, or
poorly spliced cables.
This chart is a general guideline and may not suit all applications. If cable(s) overheat (normally you can smell it), use next size larger cable.
*
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
2
( ) = mm
for metric use
***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.

5-8. Remote 14 Receptacle RC14 Information

NOTE
A
J
K
K
I
I
B
B
C L N
H
M
M
D
D
G
G
F
E
*The remaining sockets are not used.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
100 ft (30 m) or Less
10 − 60%
60 − 100%
Welding
Duty
Amperes
Cycle
Cycle
100
4 (20)
150
3 (30)
200
3 (30)
250
2 (35)
300
1 (50)
1/0 (60)
350
1/0 (60)
2/0 (70)
Engine runs at weld/power speed whenever a device connected to the remote 14
receptacle is running.
24 VOLTS AC
24 VOLTS AC
115 VOLTS AC
115 VOLTS AC
REMOTE
REMOTE
OUTPUT
OUTPUT
CONTROL
AMPERAGE
VOLTAGE
802 174-G
802 174-G
Return To Table Of Contents
Not Exceeding***
150 ft
200 ft
(45 m)
(60 m)
Duty
4 (20)
4 (20)
3 (30)
3 (30)
2 (35)
1 (50)
2 (35)
1 (50)
1/0 (60)
1 (50)
1/0 (60)
2/0 (70)
2/0 (70)
3/0 (95)
3/0 (95)
4/0 (120)
Socket*
A
24 volts ac. Protected by circuit breaker CB6.
B
Contact closure to A completes 24 volts ac
contactor control circuit.
I
115 volts ac. Protected by circuit breaker CB5.
J
Contact closure to I completes 115 volts ac
contactor control circuit.
C
Output to remote control; 0 to +10 volts dc, +10
volts dc in MIG mode.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from
remote control.
M
CC/CV select.
F
Current feedback; +1 volt dc per 100 amperes.
A/V
A/V
H
Voltage feedback; +1 volt dc per 10 output recep-
tacle volts.
G
Circuit common for 24 and 115 volts ac circuits.
GND
GND
K
Chassis common.
250 ft
300 ft
350 ft
(70 m)
(90 m)
(105 m)
10 − 100% Duty Cycle
2 (35)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
3/0 (95)
2/0 (70)
3/0 (95)
4/0 (120) 4/0 (120)
2 ea. 2/0
3/0 (95)
4/0 (120)
(2x70)
2 ea. 2/0
2 ea. 3/0
4/0 (120)
(2x70)
(2x95)
2 ea. 2/0
2 ea. 3/0
2 ea. 3/0
(2x70)
(2x95)
(2x95)
Socket Information
OM-492 Page 17
400 ft
(120 m)
1/0 (60)
3/0 (95)
2 ea. 2/0
(2x70)
2 ea. 3/0
(2x95)
2 ea. 4/0
(2x120)
S-0007-E−

Hide quick links:

Advertisement

Table of Contents
loading