Constructing The Appliance Chase; Clearances - Heat & Glo SL-550BE Owner's Manual

Table of Contents

Advertisement

B. Constructing the Appliance Chase
A chase is a vertical boxlike structure built to enclose the
gas appliance and/or its vent system. Vertical vents that
run on the outside of a building may be, but are not re-
quired to be, installed inside a chase.
Construction of the chase may vary with the type of build-
ing. These instructions are not substitutes for the require-
ments of local building codes. Local building codes MUST
be checked.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
Walls, ceiling, base plate and cantilever fl oor of the chase
should be insulated. Vapor and air infi ltration barriers
should be installed in the chase as per regional codes for
the rest of the home. Additionally, in regions where cold
air infi ltration may be an issue, the inside surfaces may be
sheetrocked and taped for maximum air tightness.
To further prevent drafts, the wall shield and ceiling
fi restops should be caulked with high temperature caulk
to seal gaps. Gas line holes and other openings should
be caulked with high temp caulk or stuffed with unfaced
B
D
DVP Pipe SL Pipe
Models
Rough
Opening
(Width)
in.
10
SL-550BE
SL-550BE-IPI
mm
254
*Dimension for rear venting with one 90º elbow.
Figure 3.2 Clearances to Combustibles
8
A
C
A
B
C
*
DVP Pipe SL Pipe
Rough
Rough
Rough
Opening
Opening
(Height)
Opening
(Width)
(Depth)
8-5/8
34-3/4
28-1/4
219
876
699
Heat & Glo • SL-550BE, SL-550BE-IPI • 2114-900 Rev. H • 2/08
insulation. If the appliance is being installed on a cement
slab, a layer of plywood may be placed underneath to pre-
vent conducting cold up into the room.
C. Clearances
Fire Risk.
Odor Risk.
• Install appliance on hard metal or wood surfaces
• Do NOT install appliance directly on carpeting,
Fire Risk.
• Construct chase to all clearance specifi cations
• Locate and install appliance to all clearance
F
J
D
E
Rough
Clearance
Combustible
Rough
Opening
to Ceiling
Opening
(Width)
(Depth)
16-1/4
37
32
413
940
813
WARNING
extending full width and depth of appliance.
vinyl, tile or any combustible material other than
wood.
WARNING
in manual.
specifi cations in manual.
FROM TOP
TO CEILING
G
I
F
G
H
Combustible
Behind
Floor
Flooring
Appliance
0
0
1/2
0
0
13
OF HOOD
E
H
I
J
Sides of
Front of
Appliance
Appliance
1/2
36
13
915

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl-550be-ipi

Table of Contents