Cleaning Instaclean ™ Fluid Filter (Prolts Sprayers Only); Cleaning Gun - Graco MAGNUM LTS 15 257060 Operation Manual

Airless sprayers
Table of Contents

Advertisement

Shutdown and Cleaning
Cleaning InstaClean
Filter (ProLTS Sprayers Only)
The InstaClean Fluid Filter prevents particles from
entering paint hose. After each use, remove and clean it
to insure peak performance.
1. Relieve pressure, page 10.
2.
a. Disconnect airless spray
hose (a) from sprayer.
b. Unscrew outlet fitting (b).
c. Remove InstaClean Fluid
Filter (c).
3. Check InstaClean Fluid Filter (c) for debris. If
needed, clean filter with water and a soft brush.
a. Install closed (square)
end of InstaClean
Fluid
Filter (c) in sprayer.
b. Screw outlet fitting (b)
into sprayer.
4. Tighten outlet fitting and
reconnect hose (a) to
sprayer. Use two wrenches to
tighten securely.
22
Fluid
b
c
a
ti9347a
c
b
ti9347a
a
ti9674b

Cleaning Gun

Clean gun fluid filter (d) with
water or flushing solvent and a
brush every time you flush the
system. Replace gun filter if
damaged.
Remove tip and guard and clean
with water or flushing solvent. A
soft brush can be used to loosen
and remove dried on material if
needed.
Wipe paint off outside of gun
using a soft cloth moistened with
water or flushing solvent.
d
ti11988a
ti9671a
313034H