7011 System components for external changeover !
Example:
Value of parameter "34" (see following
table):
Simultaneous changeover of the operat-
ing status for heating circuit with
mixer M2, e.g. to "Reduced", and for the
heating water buffer cylinder to "Top".
Value
Heating cir-
cuit without
mixer A1
"0"
—
"1"
X
"2"
—
"3"
X
"4"
—
"5"
X
"6"
—
"7"
X
"8" to "15": Do not adjust.
"16"
—
"17"
X
"18"
—
"19"
X
"20"
—
"21"
X
"22"
—
"23"
X
"24" to "31": Do not adjust.
"32"
—
"33"
X
"34"
—
"35"
X
"36"
—
"37"
X
"38"
—
"39"
X
"40" to "47": Do not adjust.
"48"
—
"49"
X
"50"
—
Heating cir-
Heating cir-
cuit with
cuit with
mixer M2
mixer M3
—
—
X
X
—
—
X
X
—
—
X
X
—
—
X
X
—
—
X
X
—
—
X
X
—
—
X
Parameter group system definition
Note
The function "Effect of external
demand on heat pump/heating cir-
cuits 7014" has higher priority than the
function "System components for
external changeover 7011".
DHW heat-
ing
—
—
—
—
—
—
—
—
X
—
X
—
X
—
X
—
—
X
—
X
—
X
—
X
X
X
X
X
X
X
X
X
—
—
—
—
—
—
—
—
X
—
X
—
X
—
X
—
—
X
—
X
—
X
(cont.)
Heating
water buffer
cylinder
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
X
X
X
X
X
X
X
X
X
X
X
105