Minimum Air Terminal Location Clearances - Napoleon BGD42N Installation And Operating Instructions Manual

Natural gas & propane vented gas fireplaces
Table of Contents

Advertisement

Available languages

Available languages

12
3.4

MINIMUM AIR TERMINAL LOCATION CLEARANCES

EN
INSTALLATIONS
CANADA
12"
A
(304.8mm)
12"
B
(304.8mm)
12"
C
(304.8mm)*
18"
D
(457.2mm)**
12"
E
(304.8mm)**
0" (0mm)
F
0" (0mm)
G
2" (50.8mm)
3' (0.9m)
H
3' (0.9m)
I
12"
J
(304.8mm)
6' (1.8m)
K
7' (2.1m) ‡
L
12"
M
(304.8mm)††
12"
N
(304.8mm)
2' (0.6m) †*
O
8' (2.4m)
P
3' (0.9m)
Q
6' (1.8m)
R
12"
S
(304.8mm)
Δ
The terminal shall not be located less than 6 feet (1.8m) under a window that opens on a horizontal plane in a structure with three walls and a roof.
*
Recommended to prevent condensation on windows and thermal breakage
**
It is recommended to maximize the distance to vinyl clad soffi ts.
***
This is a recommended distance. For additional requirements check local codes.
A vent shall not terminate where it may cause hazardous frost or ice accumulations on adjacent property surfaces..
††
Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the fl oor.
†*
Recommended to prevent recirculation of exhaust products. For additional requirements check local codes.
††*
Permitted only if the balcony is fully open on a minimum of one side.
W415-0777 / E / 08.26.13
U.S.A.
12"
Clearance above grade, veranda porch, deck or balcony.
(304.8mm)
9" (228.6mm)
Clearance to windows or doors that open.
Δ
Δ
12"
Clearance to permanently closed windows.
(304.8mm)*
18"
Vertical clearance to ventilated soffi ts located above the terminal within a horizontal distance of
(457.2mm)**
2' (0.6m) from the center line of the terminal.
12"
Clearance to unventilated soffi t.
(304.8mm)**
0" (0mm)
Clearance to an outside corner wall.
Clearance to an inside non-combustible corner wall or protruding non-combustible obstructions (chimney,
0" (0mm)
etc.).
Clearance to an inside combustible corner wall or protruding combustible obstructions (vent chase,
2" (50.8mm)
etc.).
Clearance to each side of the center line extended above the meter / regulator assembly to a
3' (0.9m)***
maximum vertical distance of 15' (4.6m).
3' (0.9m)***
Clearance to a service regulator vent outlet.
Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other
9" (228.6mm)
appliance.
3' (0.9m)
Clearance to a mechanical air supply inlet.
7' (2.1m)***
Clearance above a paved sidewalk or paved driveway located on public property.
12"
Clearance under a veranda, porch or deck.
(304.8mm)***
12"
Clearance above the roof.
(304.8mm)
2' (0.6m) †*
Clearance from an adjacent wall including neighbouring buildings.
8' (2.4m)
Roof must be non-combustible without openings.
3' (0.9m)
See chart for wider wall dimensions.
See chart for deeper wall dimensions. The terminal shall not be installed on any wall that has an
6' (1.8m)
opening between the terminal and the open side of the structure.
12"
Clearance under a covered balcony
(304.8mm)
COVERED BALCONY APPLICATIONS ††*
Q
R
Q
= 3 feet
R
MIN
= 2 x
Q
MAX
ACTUAL
(0.9m)
12.2D
S
P
G
R
MAX
(4.6m)