Napoleon BGD42N Installation And Operating Instructions Manual
Napoleon BGD42N Installation And Operating Instructions Manual

Napoleon BGD42N Installation And Operating Instructions Manual

Natural gas & propane vented gas fireplaces
Table of Contents

Advertisement

Available languages

Available languages

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22, ANSI Z21.50 FOR VENTED GAS FIREPLACES.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING
!
If the information in these instructions
are not followed exactly, a fi re or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless a
certifi ed kit is used.
Decorative Product: Not for use as a heating appliance.
Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
BGD42N
NATURAL GAS
BGD42P
PROPANE
WARNING
!
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS UNTIL
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
1.28D
EN
FR
PG
51
W415-0777 / E / 08.26.13

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon BGD42N

  • Page 1 Decorative Product: Not for use as a heating appliance. NEVER ALLOW CHILDREN TO TOUCH GLASS. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Phone (705)721-1212 • Fax (705)722-6031 • www.napoleonfi replaces.com • ask@napoleonproducts.com $10.00...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INSTALLATION OVERVIEW INTRODUCTION DIMENSIONS GENERAL INSTRUCTIONS GENERAL INFORMATION RATING PLATE INFORMATION VENTING VENTING LENGTHS AND COMPONENTS TYPICAL VENT INSTALLATIONS SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION MINIMUM AIR TERMINAL LOCATION CLEARANCES VENT APPLICATION FLOW CHART DEFINITIONS ELBOW VENT LENGTH VALUES HORIZONTAL TERMINATION VERTICAL TERMINATION INSTALLATION...
  • Page 3: Installation Overview

    1.0 INSTALLATION OVERVIEW See the section “MINIMUM MANTEL AND ENCLOSURE CLEARANCES” See the section “FRAMING” and See the sections “MINIMUM MANTEL “VENTING” and AND ENCLOSURE “INSTALLATION” CLEARANCES” for drywall (or other combustible material) See the sections “INSTALLATION and FRAMING” See the section Side “FRAMING”...
  • Page 4: Introduction

    2.0 INTRODUCTION WARNING • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. • ANY CHANGES TO THIS APPLIANCE OR IT’S CONTROLS CAN BE DANGEROUS AND IS PROHIBITED. • Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating instructions could cause fi...
  • Page 5: Dimensions

    DIMENSIONS 38 1/2" 978mm 35 1/2" 902mm INLET 21" 20" RATING PLATE 508mm 533mm 42" LOCATION 22" 1067mm 559mm GENERAL INSTRUCTIONS WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT, WITH THE GLASS DOOR OPENED OR REMOVED. PROVIDE ADEQUATE CLEARANCE FOR SERVICING AND OPERATING THE APPLIANCE.
  • Page 6: General Information

    The installation must conform with local codes or, in absence of local codes, the National Gas and Propane We suggest that our gas Installation Code CSA B149.1 in Canada, or the National Fuel Gas Code, ANSI Z223.1 / NFPA 54 in the United hearth products be installed States.
  • Page 7: Rating Plate Information

    FLOOR / PLANCHER VENT SIDES / COTES DE L'EVENT EVENT VENT 1" 1" 1" THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE SIDES / COTES VENT TOP / EVENT SUPERIEUR RIEUR 2" 2" 2" OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND...
  • Page 8: Venting

    7.2C Horizontal runs may have a 0" rise per foot in all cases using Simpson Dura-Vent, Selkirk Direct Temp, Ameri- can Metal Amerivent or Napoleon® rigid or fl exible venting components when venting, see "TYPICAL VENT INSTALLATIONS" section. For optimum performance it is recommended that all horizontal runs have a 1" (25mm) rise per foot when using Napoleon®...
  • Page 9: Venting Lengths And Components

    VENTING LENGTHS AND COMPONENTS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent and Metal-Fab follow the installation procedure provided with the venting components.
  • Page 10: Typical Vent Installations

    TYPICAL VENT INSTALLATIONS NOTE: When terminating vertically, the restrictor plate W500-0205 must be installed, see "RESTRICTING VERTICAL VENTS" section. 16" (406mm) 40FT (12m) 3FT (1m) 18" (457mm) 38 1/4" 35 1/2" (972mm) MIN (902mm) PLUS RISE* * See "VENTING" section W415-0777 / E / 08.26.13...
  • Page 11: Special Vent Installations

    SPECIAL VENT INSTALLATIONS 3.3.1 PERISCOPE TERMINATION Use the periscope kit to locate the air termination above grade. The periscope must 12" be installed so that when fi nal grading is completed, the bottom air slot is located a (305mm) minimum of 12” (304.8mm) above grade. The maximum allowable vent length MIN TO is 10’...
  • Page 12: Minimum Air Terminal Location Clearances

    MINIMUM AIR TERMINAL LOCATION CLEARANCES COVERED BALCONY APPLICATIONS ††* = 3 feet = 2 x ACTUAL (4.6m) (0.9m) INSTALLATIONS CANADA U.S.A. 12” 12” Clearance above grade, veranda porch, deck or balcony. (304.8mm) (304.8mm) 12” 9” (228.6mm) Clearance to windows or doors that open. (304.8mm) Δ...
  • Page 13: Vent Application Flow Chart

    VENT APPLICATION FLOW CHART TOP EXIT Horizontal Termination Vertical Termination Vertical rise is equal Vertical rise is equal Vertical rise is less Vertical rise is less to or greater than to or greater than than horizontal run than horizontal run the horizontal run the horizontal run Horizontal run +...
  • Page 14: Horizontal Termination

    HORIZONTAL TERMINATION ) < (V See graph to determine the required vertical Simple venting confi guration (only one 45° and 90° rise V for the required horizontal run H elbow) 40 (12.2) 39 (11.9) 30 (9.1) REQUIRED VERTICAL 20 (6.1) RISE IN FEET (METERS) V 10 (3.1)
  • Page 15 ) > (V See graph to determine the required vertical Simple venting confi guration (only one 45° and 90° rise V for the required horizontal run H elbow) 150 (3810) 147 (3733.8) REQUIRED VERTICAL RISE 100 (2540) IN INCHES (MILLIMETERS) V 57 (1447.8) 50 (1270) (1.5)
  • Page 16: Vertical Termination

    VERTICAL TERMINATION ) < (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 40 (12.2) 30 (9.1) REQUIRED VERTICAL 20 (6.1) RISE IN FEET (METERS) V 10 (3.1) 3 (0.9) (1.5) (3.1) (6.1)
  • Page 17 ) > (V Simple venting configurations. See graph to determine the required vertical rise V for the required horizontal run H 20 (6.1) 19 (5.8) REQUIRED VERTICAL RISE IN FEET 10 (3.1) (METERS) V 3 (0.9) (1.5) (3.1) (4.6) (6.1) (7.6) (9.1) HORIZONTAL VENT RUN PLUS OFFSET IN FEET (METERS)H...
  • Page 18: Installation

    4.0 INSTALLATION WARNING ENSURE TO UNPACK ALL LOOSE MATERIALS FROM INSIDE THE FIREBOX PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY. IF YOUR APPLIANCE IS SUPPLIED WITH A REMOTE ENSURE THE REMOTE RECEIVER IS IN THE “OFF” POSITION PRIOR TO HOOKING UP THE GAS AND ELECTRICAL SUPPLY TO THE APPLIANCE. FOR SAFE AND PROPER OPERATION OF THE APPLIANCE, FOLLOW THE VENTING INSTRUCTIONS EXACTLY.
  • Page 19: Horizontal Installation

    4.1.1 HORIZONTAL INSTALLATION WARNING THE FIRESTOP ASSEMBLY MUST BE INSTALLED WITH THE VENT SHIELD TO THE TOP. TERMINALS MUST NOT BE RECESSED INTO A WALL OR SIDING MORE THAN THE DEPTH OF THE RETURN FLANGE OF THE MOUNTING PLATE. This application occurs when venting through an exterior wall. Having determined the correct height for the air terminal location, cut and CAULKING frame a hole in the exterior wall as illustrated to accommodate...
  • Page 20: Vertical Installation

    4.1.2 VERTICAL INSTALLATION This application occurs when venting through a roof. Installation kits for various roof pitches are available from your authorized dealer / distributor. See accessories to order specifi c kits required. A. Determine the air terminal location, cut and frame a square opening as illustrated in the ceiling and the roof to provide the minimum 1”...
  • Page 21: Horizontal Air Terminal Installation

    4.2.1 HORIZONTAL AIR TERMINAL INSTALLATION Stretch the inner fl ex pipe to the required length taking into account the additional length needed for the fi nished wall surface. Apply a heavy bead of the CAULKING high temperature sealant W573-0007 Mill Pac (not supplied) to the inner sleeve of the air terminal.
  • Page 22: Vertical Air Terminal Installation

    4.2.2 VERTICAL AIR TERMINAL INSTALLATION WARNING MAINTAIN A MINIMUM 2” (50.8mm) SPACE BETWEEN THE AIR INLET BASE AND THE STORM COLLAR. Fasten the roof support to the roof using the screws provided. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having jurisdiction or the optional roof support.
  • Page 23: Vent Connection

    4.2.3 VENT CONNECTION Install the inner fl ex pipe to the appliance. Secure with 3 screws #8 X 1/2” SELF and fl at washers. Seal the joint and screw holes using the high DRILLING temperature sealant W573-0007 (not supplied). SCREWS Install the outer fl...
  • Page 24: Extended Horizontal Air Terminal Installation

    4.3.2 EXTENDED HORIZONTAL AIR TERMINAL INSTALLATION A. Follow the instructions for "HORIZONTAL AIR TERMINAL AIR TERMINAL INSTALLATION", items 1 to 3. TELESCOPIC SLEEVE B. Continue adding components alternating flexible and rigid vent 20" (508mm) pipes. Ensure that all inner flex vent pipes and elbows have COUPLER sufficient vent spacers attached and each component is securely VENTING...
  • Page 25: Mobile Home Installation

    MOBILE HOME INSTALLATION This appliance is also certifi ed to be installed as an OEM (Original Equipment Manufacturer) installation in a manufactured home (U.S. only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.
  • Page 26: Gas Installation

    GAS INSTALLATION WARNING RISK OF FIRE, EXPLOSION OR ASPHYXIATION. ENSURE THERE ARE NO IGNITION SOURCES SUCH AS SPARKS OR OPEN FLAMES. SUPPORT GAS CONTROL WHEN ATTACHING GAS SUPPLY PIPE TO PREVENT DAMAGING GAS LINE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 27: Framing

    5.0 FRAMING WARNING RISK OF FIRE! IN ORDER TO AVOID THE POSSIBILITY OF EXPOSED INSULATION OR VAPOUR BARRIER COMING IN CONTACT WITH THE APPLIANCE BODY, IT IS RECOMMENDED THAT THE WALLS OF THE APPLIANCE ENCLOSURE BE “FINISHED” (IE: DRYWALL / SHEETROCK), AS YOU WOULD FINISH ANY OTHER OUTSIDE WALL OF A HOME.
  • Page 28: Minimum Clearance To Combustibles

    MINIMUM CLEARANCE TO COMBUSTIBLES Minimum clearance to combustible construction from appliance and vent surfaces: Sides, back, bottom and top of the unit 0" Recessed depth 22" (559mm) All around the vent pipe* 2" (51mm) Enclosure top 45 1/2" (1156mm) Ceiling 54"...
  • Page 29: Minimum Enclosure Clearances

    MINIMUM ENCLOSURE CLEARANCES NON-COMBUSTIBLE COMBUSTIBLE 0” IF NON- COMBUSTIBLE 2" FINISHING IS 51mm USED SUCH AS BRICK AND STONE 10" 254mm 3 1/4" 83mm 2" 51mm 38 1/4" BRICK 972mm 45 1/2" MINIMUM 1156mm PLUS RISE* 2" 51mm The appliance requires a minimum enclosure height of 45 1/2" (1156mm). For temperature requirements, the enclosure space around and above the appliance must be left unobstructed.
  • Page 30: Alcove Enclosure

    ALCOVE ENCLOSURE RECESS OR ALCOVE AREA ENCLOSURE AREA APPLIANCE NOTE: Recesses or alcoves above the appliance can be made as deep as desired provided the minimum clearances to combustibles are maintained. Non-combustible material can be used, provided the minimum clearances to combustible materials are applied. The minimum enclosure volume must be increased by no less than the volume of the recess.
  • Page 31: Non-Combustible Facing Material

    NON-COMBUSTIBLE FACING MATERIAL NON-COMBUSTIBLE FINISH FACING MATERIAL FRONT OF FINISH MATERIAL MATERIAL APPLIANCE 2" (51mm) 4" (102mm) TOP OF 4" (102mm) 6" (152mm) APPLIANCE 2" (51mm) 0" (0mm) 0" (0mm) NON-COMBUSTIBLE 2" (51mm) FACING MATERIAL 4" (102mm) 6" (152mm) 4" (102mm) 2"...
  • Page 32: Finishing

    6.0 FINISHING WARNING RISK OF FIRE! NEVER OBSTRUCT THE FRONT OPENING OF THE APPLIANCE. THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT GO BELOW THE SPECIFIED DIMENSION AS ILLUSTRATED. DO NOT STRIKE, SLAM OR SCRATCH GLASS.
  • Page 33: L42 Louvre Installation

    L42 LOUVRE INSTALLATION UPPER LOUVRES Insert the louvre tabs into the slots located at the top left and right corners of the unit. SLOT LOWER LOUVRES Insert the hinge clips into the slots lo- HINGE cated at the bottom left and right corners CLIP of the unit.
  • Page 34: Log Placement

    THE LOGS ARE FRAGILE AND SHOULD BE HANDLED WITH CARE. 76.1A Phazer logs and glowing embers, exclusive to Napoleon Fireplaces, provide a unique and realistic glowing ® effect that is different in every installation. Take the time to carefully position the glowing embers for a maxi- mum glowing effect.
  • Page 35: Glowing Embers

    GLOWING EMBERS Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of GLOWING EMBERS the small logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fi...
  • Page 36: Optional Blower Installation

    7.0 OPTIONAL BLOWER INSTALLATION WARNING RISK OF FIRE AND ELECTRICAL SHOCK. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THIS APPLIANCE. USE ONLY WOLF STEEL APPROVED OPTIONAL ACCESSORIES AND REPLACEMENT PARTS WITH THIS APPLIANCE. USING NON-LISTED ACCESSORIES (BLOWERS, DOORS, LOUVRES, TRIMS, GAS COMPONENTS, VENTING COMPONENTS, ETC.) COULD RESULT IN A SAFETY HAZARD AND WILL VOID THE WARRANTY AND CERTIFICATION.
  • Page 37: Operation

    8.0 OPERATION WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RUN OUT WITH THE GLASS DOOR OPENED OR REMOVED.
  • Page 38: Adjustments

    9.0 ADJUSTMENTS PILOT BURNER ADJUSTMENT Adjust the pilot screw to provide properly sized fl ame. Turn in a clockwise PILOT direction to reduce the gas fl ow. BURNER THERMOPILE Inlet pressure can be checked by turning screw (A) THERMOCOUPLE counter-clockwise until loosened and then placing pressure gauge tubing over the test point.
  • Page 39: Flame Characteristics

    FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustrations provided. If any fl ames 3/8” - 1/2” appear abnormal call a service person. (9.5mm - 12.7mm) FLAME MUST ENVELOP UPPER 3/8"...
  • Page 40: Annual Maintenance

    10.1 ANNUAL MAINTENANCE WARNING THE FIREBOX BECOMES VERY HOT DURING OPERATION. LET THE APPLIANCE COOL COMPLETELY OR WEAR HEAT RESISTANT GLOVES BEFORE CONDUCTING SERVICE. NEVER VACUUM HOT EMBERS. DO NOT PAINT THE PILOT ASSEMBLY. • This appliance will require maintenance which should be planned on an annual basis. •...
  • Page 41: Care Of Plated Parts

    10.3 CARE OF PLATED PARTS If the appliance is equipped with plated parts, you must clean fi ngerprints or other marks from the plated surfaces before operating the appliance for the fi rst time. Use a glass cleaner or vinegar and towel to clean. If not cleaned properly before operating for the fi...
  • Page 42: Replacements

    NATURAL GAS PILOT ASSEMBLY W455-0069 NATURAL GAS PILOT INJECTOR W455-0068 PROPANE GAS PILOT INJECTOR W725-0025 NATURAL GAS VALVE W725-0026 PROPANE VALVE W385-0334 NAPOLEON® LOGO W750-0112 20FT OF WIRE W010-0864 PAN BURNER GL-658 LOG SET W361-0016 GLOWING EMBERS W550-0001 CHARCOAL EMBERS...
  • Page 43 FLEXIBLE VENT KITS REF NO. PART NO. DESCRIPTION GD420 (5 FT) W010-0772 5" (127mm) FLEXIBLE VENT PIPE - (5 FT / 1.5m) C/W SPACERS W730-0012 8" (203mm) FLEXIBLE VENT PIPE - (5 FT / 1.5m) GD430 (10 FT) W730-0013 8" (203mm) FLEXIBLE VENT PIPE - (10 FT / 3m) W010-0773 5"...
  • Page 44 ACCESSORIES REF NO. PART NO. DESCRIPTION GD36 THERMOSTATIC SENSOR CONTROL KIT - FOR USE WITH GD65 ONLY W500-0033 VARIABLE SPEED SWITCH WALL MOUNTING PLATE KB35 VARIABLE SPEED SWITCH GA-566 HOT AIR DISTRIBUTION KIT W690-0005 THERMOSTAT - 110V - FOR USE WITH GA-566 ONLY GA-70 EXTENSION KIT - 5FT GA-72...
  • Page 45: Trouble Shooting

    12.0 TROUBLE SHOOTING WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED. DO NOT USE ABRASIVE CLEANERS.
  • Page 46 SYMPTOM PROBLEM TEST SOLUTION Pilot will not light. No spark at pilot burner. Check if pilot can be lit by a match. Check that the wire is connected to the push button igniter. Check if the push button igniter needs tightening. Replace the wire if the wire insulation is broken or frayed.
  • Page 47 SYMPTOM PROBLEM TEST SOLUTION White / grey fi lm forms. Sulphur from fuel is being Clean the glass with a recommended gas appliance deposited on glass, logs or glass cleaner. combustion chamber surfaces. DO NOT CLEAN GLASS WHEN HOT. If deposits are not cleaned off regularly, the glass may become permanently marked.
  • Page 48: Warranty

    All parts replaced under the President’s Limited Lifetime Warranty Policy are subject to a single claim. During the fi rst 10 years NAPOLEON® will replace or repair the defective parts covered by the lifetime warranty at our discretion free of charge. From 10 years to life, NAPOLEON®...
  • Page 49: Service History

    14.0 SERVICE HISTORY 43.1 W415-0777 / E / 08.26.13...
  • Page 50 Fireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces • Outdoor Fireplaces • Gourmet Grills 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...
  • Page 51 APPOSEZ L’ÉTIQUETTE DU NUMÉRO DE SÉRIE DU CARTON ENFANTS TOUCHER LA VITRE. N° de série N° DE MODÈLE Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-722-6031 • www.napoleonfoyers.com • ask@napoleon.on.ca 10,00$ 1.28C...
  • Page 52 TABLE DES MATIÈRES VUE D’ENSEMBLE DE L’INSTALLATION INTRODUCTION DIMENSIONS INSTRUCTIONS GÉNÉRALES INFORMATION GÉNÉRALE INFORMATION SUR LA PLAQUE D'HOMOLOGATION ÉVACUATION LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS INSTALLATIONS TYPIQUES D'ÉVENTS INSTALLATIONS PARTICULIÈRES D'ÉVENTS 3.3.1 ENSEMBLE PÉRISCOPIQUE EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON CHARTE D'APPLICATION DES ÉVACUATIONS LÉGENDE VALEURS DU COUDE EN LONGUEURS D'ÉVENT...
  • Page 53: Vue D'ensemble De L'installation

    1.0 VUE D’ENSEMBLE DE L’INSTALLATION Voir la section « DÉGAGEMENTS MINIMAL DE LA TABLETTE DE L’ENCEINTE » . Voir la section « DÉGAGEMENTS Voir la section MINIMAUX DE « ÉVACUATION » et L’ENCEINTE » pour « INSTALLATION» cloison sèche (ou autre matériau combustible) Voir la section...
  • Page 54: Introduction

    2.0 INTRODUCTION AVERTISSEMENT • CET APPAREIL EST CHAUD LORSQU’IL FONCTIONNE ET PEUT CAUSER DE GRAVES BRÛLURES EN CAS DE CONTACT. • TOUTE MODIFICATION APPORTÉE À CET APPAREIL OU AUX CONTRÔLES PEUT ÊTRE DANGEREUX ET EST INTERDIT. • Ne faites pas fonctionner l’appareil avant d’avoir lu et compris les instructions d’opération. Omettre d’utiliser l’appareil selon les instructions d’opération pourrait causer un incendie ou des blessures.
  • Page 55: Dimensions

    DIMENSIONS 38 1/2" 978mm 35 1/2" 902mm ENTRÉE DU GAZ 21" 20" 533mm 508mm 42" 22" 1067mm 559mm INSTRUCTIONS GÉNÉRALES AVERTISSEMENT ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE. PRÉVOYEZ UN ACCÈS SUFFISANT POUR ENTRETENIR ET OPÉRER L’APPAREIL.
  • Page 56: Information Générale

    • La soupape d’arrêt doit être un robinet à gaz avec une poignée en T. • Le raccord fl exible ne doit pas mesurer plus que 36 pouces (914.4mm). • Un détecteur de monoxyde de carbone est requis dans toutes les pièces contenant des appareils alimentés au gaz. •...
  • Page 57: Information Sur La Plaque D'homologation

    LE FABRICANT. FLOOR / PLANCHER VENT SIDES / COTES DE L'EVENT L'EVENT 1" THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON VENT KITS. SEE SIDES / COTES VENT TOP / EVENT SUPERIEUR PERIEUR 2" OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS. PROPER REINSTALLATION AND...
  • Page 58: Évacuation

    3.0 ÉVACUATION AVERTISSEMENT RISQUE D’INCENDIE. CONSERVEZ LES DÉGAGEMENTS NÉCESSAIRES AU CONDUIT D’ÉVENT ET À L’APPAREIL. SI LE SYSTÈME D’ÉVENT EST FOURNI AVEC DES ESPACEURS, LES COURSES HORIZONTALES ET VERTICALES DU SYSTÈME DOIVENT ÊTRE SUPPORTÉES À TOUS LES 3 PI (0,9m). UTILISEZ DES SUPPORTS OU DES ATTACHES INCOMBUSTIBLES ÉQUIVALENTS AFIN DE MAINTENIR LE DÉGAGEMENT AUX MATÉRIAUX COMBUSTIBLES.
  • Page 59: Longueurs Des Conduits D'évacuation Et Composants

    LONGUEURS DES CONDUITS D’ÉVACUATION ET COMPOSANTS Utilisez uniquement des composants d’évacuation Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent ou Metal-Fab. Les minimums et maximums des longueurs d’évent, pour les installations verticales et horizontales, et les emplacements des terminaisons pour les deux systèmes sont précisés dans ce manuel et doivent être respectés.
  • Page 60: Installations Typiques D'évents

    INSTALLATIONS TYPIQUES D'ÉVENTS NOTE : Lorsque l'évacuation se termine verticalement, vous devez installer la plaque de restriction W500-0205. Référez-vous à la section « ÉTRANGLEMENT DES ÉVENTS VERTICAUX ». 16” (406MM) MINIMUM 3 PIEDS (1M) MINIMUM 40 PIEDS (12M) MAXIMUM 18" (457MM) 38 1/4"...
  • Page 61: Installations Particulières D'évents

    INSTALLATIONS PARTICULIÈRES D'ÉVENTS 3.3.1 ENSEMBLE PÉRISCOPIQUE Utilisez l’ensemble périscopique afi n de positionner la terminaison au-dessus du niveau du sol. L’ensemble périscopique doit être installé de façon à ce que la fente d’air du bas soit située à un 12" (305MM) MIN minimum de 12 pouces (304,8mm) au-dessus du AU NIVEAU niveau du sol.
  • Page 62: Emplacements Et Dégagements Minimaux De La Terminaison

    EMPLACEMENTS ET DÉGAGEMENTS MINIMAUX DE LA TERMINAISON ††* APPLICATIONS POUR BALCON COUVERT INSTALLATION = 3 pieds = 2 x RÉELLE (0,9m) (4,6m) CANADA É.-U. 12” 12” Dégagement au-dessus du sol, d’une véranda, d’une terrasse en bois ou d’un balcon. (304,8mm) (304,8mm) 12”...
  • Page 63: Charte D'application Des Évacuations

    CHARTE D'APPLICATION DES ÉVACUATIONS ÉVACUATION SUR LE DESSUS Terminaison horizontale Terminaison verticale La course verticale La course verticale La course verticale La course verticale est plus grande ou est plus grande ou est plus petite est plus petite égale à la course égale à...
  • Page 64: Terminaison Horizontale

    TERMINAISON HORIZONTALE ) < (V Configuration d'évacuation simple (un coude de 45º et Consultez le graphique pour déterminer la course verticale de 90° seulement) nécessaire V par rapport à la course horizontale requise H 39 (11,9) 30 (9,1) COURSE VERTICALE REQUISE EN 20 (6,1) PIEDS...
  • Page 65 ) > (V Consultez le graphique pour déterminer la Confi guration d’évacuation simple (un coude de 45º et course verticale nécessaire V par rapport à la de 90°seulement) course horizontale requise H 150 (3810) 147 (3733.8) COURSE VERTICALE 100 (2540) REQUISE EN POUNCES (MILLIMETERS) V...
  • Page 66: Terminaison Verticale

    TERMINAISON VERTICALE ) < (V Configurations d'évacuation simple. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 40 (12,2) 30 (9,1) COURSE VERTICALE REQUISE EN PIEDS 20 (6,1) (MÈTRES)V 10 (3,1) 3 (0,9) (1,5) (3,1)
  • Page 67 ) > (V Configurations d'évacuation simple. Consultez le graphique pour déterminer la course verticale nécessaire V par rapport à la course horizontale requise H 20 (6,1) 19 (5,8) COURSE VERTICALE REQUISE EN 10 (3,1) PIEDS (MÈTRES) V 3 (0,9) (7,6) (9,1) (1,5) (3,1)
  • Page 68: Installation

    4.0 INSTALLATION AVERTISSEMENT AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE, ASSUREZ-VOUS DE RETIRER TOUTE COMPOSANTE NON FIXÉE À L’INTÉRIEUR DE LA CHAMBRE DE COMBUSTION. SI VOTRE APPAREIL COMPREND UN SYSTÈME DE TÉLÉCOMMANDE, ASSUREZ-VOUS QUE LE RÉCEPTEUR EST À LA POSITION « OFF » AVANT D’EFFECTUER LES BRANCHEMENTS POUR L’ALIMENTATION EN GAZ ET ÉLECTRIQUE.
  • Page 69: Installation Horizontale

    4.1.1 INSTALLATION HORIZONTALE AVERTISSEMENT L’ESPACEUR COUPE-FEU DOIT ÊTRE INSTALLÉ AVEC L’ÉCRAN PROTECTEUR ORIENTÉ VERS LE HAUT. LA TERMINAISON NE DOIT PAS ÊTRE ENCHÂSSÉE DANS LE MUR OU LE REVÊTEMENT EXTÉRIEUR PLUS QUE L’ÉPAISSEUR DE LA BRIDE DE LA PLAQUE DE MONTAGE. Cette confi...
  • Page 70: Installation Verticale

    4.1.2 INSTALLATION VERTICALE Cette confi guration s’applique lorsque l’évacuation se fait à travers un toit. Des ensembles d’installation pour les différentes pentes de toit sont disponibles chez votre détaillant autorisé. Voir la section « Accessoires » pour commander l’ensemble spécifi que dont vous avez besoin. Une fois que vous aurez déterminé...
  • Page 71: Installation De La Terminaison Horizontale

    4.2.1 INSTALLATION DE LA TERMINAISON HORIZONTALE Étirez la gaine fl exible intérieure à la longueur re- quise en tenant compte de la longueur additionnelle GAINE FLEXIBLE nécessaire pour la surface du mur fi ni. Appliquez EXTÉRIEURE un généreux joint de scellant à haute température CALFEUTRAGE W573-0007 Mill Pac (non fourni).
  • Page 72: Installation De La Terminaison Verticale

    4.2.2 INSTALLATION DE LA TERMINAISON VERTICALE AVERTISSEMENT CONSERVEZ UN ESPACE MINIMAL DE 2" (50,8mm) ENTRE LA BASE DE LA PRISE D’AIR ET LE COLLET DE SOLIN. Fixez le support de toit au toit à l’aide des vis fournies. Le support de toit est optionnel.
  • Page 73: Raccordement Des Évents À L'appareil

    4.2.3 RACCORDEMENT DES ÉVENTS À L'APPAREIL Raccordez la gaine fl exible intérieure à l’appareil. Fixez-la à l’aide de trois vis et de trois rondelles. Scellez le joint et les têtes de vis AUTOPERCEUSES avec du scellant à haute température W573-0007 (non fourni). #8 X 1/2”...
  • Page 74: Installation Étendue De La Terminaison Horizontale

    4.3.2 INSTALLATION ÉTENDUE DE LA TERMINAISON HORIZONTALE A. Suivez les instructions dans la section « INSTALLATION DE LA TERMINAISON TERMINAISON HORIZONTALE », étapes 1 à 3. MANCHON TÉLESCOPIQUE B. Continuez d’ajouter des composants en alternant les conduits BAGUE flexibles et rigides. Assurez-vous que toutes les gaines flexibles D’ACCOUPLEMENT DE 20"...
  • Page 75: Installation Dans Une Maison Mobile

    INSTALLATION DANS UNE MAISON MOBILE Cet appareil est certifi é pour être installé comme équipement d’origine (OEM) dans une maison préfabriquée ou une maison mobile. Son installation doit être effectuée en respectant les directives du fabricant et le Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, aux États-Unis, ou les normes actuelles pour les maisons mobiles, CAN/CSA Z240 SÉRIE MH, au Canada.
  • Page 76: Installation De L'interrupteur Mural Optionnel

    INSTALLATION DE L’INTERRUPTEUR MURAL OPTIONNEL AVERTISSEMENT NE RACCORDEZ PAS L’INTERRUPTEUR MURAL, LE THERMOSTAT OU LA SOUPAPE DE GAZ À L’ALIMENTATION ÉLECTRIQUE DE 110 VOLTS. Pour faciliter l’accès, un interrupteur mural ou un thermostat millivolt optionnel peut être installé à un endroit pratique.
  • Page 77 NOTE : Ne construisez rien dans cet espace - il doit demeurer libre afin de fournir le dégagement approprié aux conduits d’évent dans cet espace de 14” de largeur centré le long de l’avant de l’appareil. Aucun matériau combustible n’est permis. 3 1/2"...
  • Page 78: Dégagements Minimaux Aux Matériaux Combustibles

    DÉGAGEMENTS MINIMAUX AUX MATÉRIAUX COMBUSTIBLES Dégagements minimaux de l'appareil et des surfaces d’évacuation aux matériaux combustibles : Côtés, arrière, plancher et dessus de l'appareil 0" Profondeur de l'enclave 22" (559mm) Au dessous et sur les côtés de l’évent* 2" (51mm) Haut de l’enceinte 45 1/2"...
  • Page 79: Dégagements Minimaux De L'enceinte

    DÉGAGEMENTS MINIMAUX DE L'ENCEINTE INCOMBUSTIBLE COMBUSTIBLE 0” SI UN MATÉRIAU DE FINITION 2" INCOMBUSTIBLE 51mm EST UTILISÉ TEL QUE DE LA BRIQUE 10" ET DE LA PIERRE 254mm 3 1/4" 83mm 2" 51mm 38 1/4" BRIQUE 972mm 45 1/2" MINIMUM 1156mm PLUS L’ÉLÉVATION* 2"...
  • Page 80: Installation En Alcôve

    INSTALLATION EN ALCÔVE ZONE ENCASTRÉE OU ALCÔVE ZONE ENCEINTE APPAREIL NOTE : Les zones encastrées ou les alcôves au dessus de l'appareil peuvent être aussi profondes que désiré tant que les dégagements minimaux aux matériaux combustibles sont respectés. Vous pouvez utiliser un matériau incombustible, pourvu que les dégagements minimaux aux matériaux combustibles soient appliqués.
  • Page 81: Matériaux De Finition Incombustibles

    MATÉRIAUX DE FINITION INCOMBUSTIBLES INCOMBUSTIBLE LA FACE DE L’APPAREIL LA FACE DE 4" (102mm) 2" (51mm) L’APPAREIL 2" (51mm) 4" (102mm) 0" (0mm) 6" (152mm) 6" (152mm) 0" (0mm) INCOMBUSTIBLE 4" (102mm) 2" (51mm) 2" (51mm) 4" (102mm) AVERTISSEMENT: Les matériaux de finition incombustibles ne doivent pas dépasser de la sommet, du fond ou des côtés de l’appareil, comme illutsrée (pour une projection maximale de 6”...
  • Page 82: Finitions

    6.0 FINITIONS AVERTISSEMENT RISQUE D’INCENDIE! N’OBSTRUEZ JAMAIS L’OUVERTURE SUR LE DEVANT DE L’APPAREIL. LA FAÇADE DE L’APPAREIL DOIT ÊTRE FAITE DE MATÉRIAUX INCOMBUSTIBLES COMME DE LA BRIQUE, DU MARBRE, DU GRANITE, ETC., À CONDITION QUE CES MATÉRIAUX NE SE TROUVENT PAS EN DEÇÀ...
  • Page 83: Installation Des Persiennes L42

    INSTALLATION DES PERSIENNES L42 PERSIENNES SUPÉRIEURES Insérez les pattes des persiennes dans les fentes situées aux coins supérieurs gauche et droit de l’appareil. FENTE PATTE PERSIENNES INFÉRIEURES Insérez les charnières à pince dans les CHARNIÈRE fentes situées aux coins inférieurs À...
  • Page 84: Disposition Des Bûches

    DISPOSITION DES BÛCHES AVERTISSEMENT OMETTRE DE POSITIONNER LES BÛCHES CONFORMÉMENT AUX SCHÉMAS OU OMETTRE D’UTILISER UNIQUEMENT DES BÛCHES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. LES BÛCHES DOIVENT ÊTRE PLACÉES CORRECTEMENT À L’INTÉRIEUR DE L’APPAREIL. NE CHANGEZ PAS LA POSITION DES BÛCHES CAR L’APPAREIL RISQUE DE NE PAS FONCTIONNER ADÉQUATEMENT ET UN RETARD D’ALLUMAGE RISQUE DE SE PRODUIRE.
  • Page 85: Braises Incandescentes

    BRAISES INCANDESCENTES Déchirez les braises incandescentes en morceaux et placez-les le long de la première rangée des orifi ces du brûleur en couvrant toute la surface à l’avant des petites BRAISES INCANDESCENTES bûches. Les braises devraient être déchirées très soigneu- sement en petits morceaux minces irréguliers, car seuls les côtés exposés des fi...
  • Page 86: Installation De La Soufflerie Optionnelle

    7.0 INSTALLATION DE LA SOUFFLERIE OPTIONNELLE AVERTISSEMENT RISQUE D’INCENDIE ET DE CHOC ÉLECTRIQUE. COUPEZ L’ALIMENTATION EN GAZ ET L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER À L’ENTRETIEN DE L’APPAREIL. N’UTILISEZ QUE LES ACCESSOIRES OPTIONNELS ET LES PIÈCES DE RECHANGE APPROUVÉS PAR WOLF STEEL POUR CET APPAREIL.
  • Page 87 INTERRUPTEUR THERMIQUE Fixez l’interrupteur à vitesse variable à l’aide de l’écrou fourni à cet effet. Branchez le cordon d’alimentation dans le réceptacle. Le harnais de RÉCEPTACLE / fils fourni dans cet ensemble est un harnais BOÎTE DE DÉRIVATION universel. Lors de son installation, assurez-vous BOUTON DE que tout excès de fil est confiné, l'empêchant CONTRÔLE...
  • Page 88: Fonctionnement

    8.0 FONCTIONNEMENT AVERTISSEMENT SI CES INSTRUCTIONS NE SONT PAS SUIVIES À LA LETTRE, UN INCENDIE OU UNE EXPLOSION POUR- RAIENT S’ENSUIVRE, CAUSANT DES DOMMAGES MATÉRIELS, DES BLESSURES CORPORELLES OU DES PERTES DE VIE. ALLUMEZ TOUJOURS LA VEILLEUSE, QUE CE SOIT POUR LA PREMIÈRE FOIS OU LORSQUE L’APPROVISIONNEMENT EN GAZ EST ÉPUISÉ, AVEC LA PORTE VITRÉE OUVERTE OU RETIRÉE.
  • Page 89: Réglages

    9.0 RÉGLAGES RÉGLAGE DE LA VEILLEUSE Ajustez la vis de la veilleuse pour obtenir une fl amme de taille normale. VEILLEUSE Tournez vers la droite pour réduire l’apport de gaz. THERMOPILE Pour vérifi er la pression d’arrivée, tournez la vis (A) vers la THERMOCOUPLE gauche jusqu’à...
  • Page 90: Caractéristiques De La Flamme

    CARACTÉRISTIQUES DE LA FLAMME Il est important d’effectuer périodiquement une inspection visuelle de la fl amme de la veilleuse et du brûleur. Comparez-les à ces illustrations. Si des fl ammes paraissent anormales, contactez un technicien de service. 3/8” - 1/2” (9,5mm - 12,7mm) LA FLAMME DOIT ENVELOPPER LA...
  • Page 91: Entretien Annuel

    10.3 ENTRETIEN ANNUEL AVERTISSEMENT LE CAISSON DEVIENT TRÈS CHAUD LORS DU FONCTIONNEMENT. LAISSEZ L’APPAREIL SE REFROIDIR COMPLÈTEMENT OU PORTEZ DES GANTS ANTICHALEUR AVANT D’EFFECTUER L’ENTRETIEN. NE JAMAIS ASPIRER DES BRAISES QUI SONT CHAUDES. NE PEINTUREZ PAS L’ASSEMBLAGE DE LA VEILLEUSE. •...
  • Page 92: Remplacement De La Vitre / Porte

    10.4 REMPLACEMENT DE LA VITRE / PORTE AVERTISSEMENT N’UTILISEZ PAS DE MATÉRIAUX DE SUBSTITUTION. LA VITRE PEUT ÊTRE CHAUDE, NE TOUCHEZ PAS LA VITRE JUSQU’À CE QU’ELLE AIT REFROIDI. USEZ DE PRUDENCE LORSQUE VOUS ENLEVEZ ET JETEZ DES DÉBRIS DE VERRE OU DES COMPOSANTS ENDOMMAGÉS.
  • Page 93: Rechanges

    11.0 RECHANGES AVERTISSEMENT OMETTRE DE POSITIONNER LES PIÈCES CONFORMÉMENT À CE MANUEL OU D’UTILISER UNIQUEMENT DES PIÈCES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. ** CECI EST UN THERMOCOUPLE À ACTION RAPIDE QUI CONSTITUE UN COMPOSANT ESSENTIEL DE SÉCURITÉ.
  • Page 94 ENSEMBLES D'ÉVENTS FLEXIBLES Nº RÉF. BGD42 DESCRIPTION GD420 (5PI) W010-0772 GAINE FLEXIBLE DE 5" (127MM) (5 PIEDS / 1.5M) AVEC ESPACEURS W730-0012 GAINE FLEXIBLE DE 8" (203MM) (5 PIEDS / 1.5M) GD430 (10PI) W730-0013 GAINE FLEXIBLE DE 8" (203MM) (10 PIEDS / 3M) W010-0773 GAINE FLEXIBLE DE 5"...
  • Page 95 ACCESSOIRES Nº RÉF. BGD42 DESCRIPTION GD36 CONTRÔLE THERMOSTATIQUE - POUR EMPLOI AVEC LE GD65 SEULEMENT W500-0033 PLAQUE MURALE POUR INTERRUPTEUR À VITESSE VARIABLE KB35 INTERRUPTEUR À VITESSE VARIABLE GA-566 ENSEMBLE DE DISTRIBUTION D'AIR CHAUD W690-0005 THERMOSTAT - 110 V - POUR EMPLOI AVEC LE GA-566 GA-70 ENSEMBLE DE RALLONGE - 5 PI GA-72...
  • Page 96: Guide De Dépannage

    12.0 GUIDE DE DÉPANNAGE WARNING ALWAYS LIGHT THE PILOT WHETHER FOR THE FIRST TIME OR IF THE GAS SUPPLY HAS RAN OUT, WITH THE GLASS DOOR OPEN OR REMOVED. TURN OFF THE GAS AND ELECTRICAL POWER BEFORE SERVICING THE APPLIANCE. APPLIANCE MAY BE HOT, DO NOT SERVICE UNTIL APPLIANCE HAS COOLED.
  • Page 97 SYMPTÔME PROBLÉME SOLUTIONS La veilleuse ne Aucune étincelle au brûleur de Vérifi ez si la veilleuse peut être allumée avec une allumette. s’allume pas. la veilleuse. Vérifi ez si le fi l est raccordé au bouton-poussoir d’ignition. Vérifi ez si le bouton-poussoir d’ignition doit être resserré. VEILLEUSE Remplacez le fi...
  • Page 98 SYMPTÔME PROBLÈME SOLUTIONS Une pellicule Le souffre du combustible Nettoyez la vitre avec un nettoyeur recommandé. NE PAS NETTOYER LORSQU’ELLE EST CHAUDE. blanche ou grise se se dépose sur la vitre, les Si vous ne nettoyez pas les dépôts régulièrement, la vitre risque de forme.
  • Page 99: Garantie

    13.0 GARANTIE Les produits Napoléon® sont fabriqués conformément aux normes strictes du Certifi cat d’Assurance de la Qualité mondialement reconnu ISO 9001 : 2008. Les produits Napoléon® sont conçus avec des composants et des matériaux de qualité supérieure, assemblés par des artisans qualifi...
  • Page 100 Poêles à bois • Produits HVAC • Foyers électriques • Foyers extérieurs • Grils à gaz de qualité 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...