ACCESSORY EQUIPMENT HOOK-UP
IMPORTANT - remove power from the operator before
attempting to connect an accessory device or control station.
All accessory equipment is connected to the terminal strips
located on the control panel of the RSX4000.
There are 11 command inputs available to the installer on the
RSX4000 in addition to 4 commons. To trigger any of these
inputs, a switch or relay closure to the common terminal for a
duration longer than 100 milliseconds and of a resistance of less
than 100 ohms is necessary. See the INPUT COMMANDS
Reference Chart on Page 19 for an explanation of each of the
inputs.
The RSX4000 has a transformer mounted on the chassis to
power accessory equipment. The maximum power that can be
supplied by this transformer is 5VA or about 1/4 Ampere at
24VAC. This is only intended to supply power to a radio
receiver. A Separate power supply is required for loop detectors
or card or key pads.
111797
10
9
111798
8
7
6
5
4
3
2
1
A
WIRING RADIO RECEIVERS
Radio Receivers may be either 3 wire (terminal) or 4 wire units.
THREE TERMINAL RECEIVERS
If a three wire receiver is to be used, the #1 terminal of the receiver is
normally COMMON to both the auxiliary transformer (power input)
and the radio relay. Most radio manufacturers label this terminal as
24 VAC. Connect a wire from the #1 terminal of the radio receiver to
terminal #1 on the operator control panel (24 VAC). The #2 terminal
of the radio receiver is normally the relay contact of the receiver.
Connect a wire from this #2 terminal of the radio receiver to the #2
terminal (ALTERNATE) on the RSX4000 control panel. The #3
terminal of the radio receiver is usually labeled RADIO POWER and
is connected to 24 VAC. Connect to terminal #2 (24 VAC) of the
RSX4000 control panel.
FOUR WIRE RECEIVERS
Four wire receivers replace the "spade" terminals on the RECEIVER
with 4 wires. These wires are typically color coded. The instructions
with the receiver must be carefully followed to properly connect the
receiver. For any 4 wire receiver, two of the wires will be for power
input and two will be for the relay contacts. Connect the two wires
C
16
16
16
16
15
14
13
12
11
Figure 14:
Terminal Strips
C
B
: INSTALLING THE OPERATOR
for the power input to each side of the 24VAC RSX4000 terminals
#1 and #2. Connect one of the two wires for the relay to terminal #16
(COMMON) and the other wire to terminal #3 (ALTERNATE) on
the RSX1000 control panel terminal strip. See Figure 16 for
connecting 4 wire receivers.
110120
CONNECT TO #3 OR #4 DEPENDING
ON DESIRED FUNCTION (SEE PG.15)
DRY CONTACT
RELAY OUTPUT
24VAC POWER
FOR RECEIVER
Figure 16: Wiring 4-Wire Receiver
WIRING FOUR-WIRE RECEIVER
WIRING A 3-BUTTON STATION
NOTE: THREE BUTTON STATIONS MAY BE ORDERED
WITH THE STOP BUTTON AS NORMALLY OPEN OR
NORMALLY CLOSED. THE RSX4000 WILL OPERATE ONLY
WITH A NORMALLY OPEN STOP BUTTON. See Figure 17 for
instructions on wiring a three button station.
110121
OPEN
CLOSE
STOP
WIRING A KEYPAD, CARD READER OR
TELEPHONE ENTRY SYSTEM
These devices activate the RSX4000 by a relay contact closure
within the device. Typically, two wires or terminals are provided by
the device to operate the gate. Follow the manufacturers instructions
on locating these connections. If one of the connections at the device
IMPROPER WIRING COULD CAUSE
ELECTROCUTION OR DAMAGE TO
CIRCUITRY. FOLLOW ALL LOCAL
ELECTRICAL CODES OR THE NATIONAL
ELECTRICAL CODE.
TERMINAL
STRIP
16
COMMON
6
OPEN
4
RADIO OPEN
3
ALTERNATE
2
24 VAC
1
24 VAC
TERMINAL
STRIP
16
8
7
6
Figure 17: 3-Button
Station Wiring
WARNING!
17
COMMON
STOP
CLOSE
OPEN

Advertisement

Table of Contents
loading