Section B: Preparing The Site; The Concrete Operator Pad; Alternate Post Mount - Linear Twist'R Plus SX4000 Owner's Manual

Vehicular swing gate operator
Table of Contents

Advertisement

6
B
: PREPARING THE SITE
111877
Figure 5: Pad Configuration
THE CONCRETE PAD
The standard RSX4000 is designed to operate a single leaf gate. Bi-
parting gate systems are possible with the addition of a second
RSX4000 operator. (Consult the factory.) Each RSX4000 has its own
dedicated control board contained within the operator cover. Care
must be taken to provide separate high voltage and low voltage
conduits to each operator. (See Figures 5 and 6.) Care must also be
taken in choosing proper placement of the conduit to avoid
interference with the swinging crank arm which connects to the output
shaft. See Figure 8A for basic dimensions and guidelines. Figure 10
illustrates the full sweeping area which the crank arm will encompass
in a typical gate installation.
If the optional pedestal kit is used, the Installation of the RSX4000
Mechanical Unit will
require a suitable concrete
pad as a mounting base. The
dimensions of the concrete
pad should be sufficient to
allow at least 5" of
clearance from each edge of
the pad to the nearest
pedestal mounting hole. The
top of the pad should be at
least 3" above grade to raise
the operator above any
standing water. The depth of
the pad below grade is
dependent on the weight and
size of the gate and the soil
conditions at the site of the
If a suitable concrete base already exists for
mounting the operator it will be necessary to drill
mounting holes for the RSX4000 operator. 3/4"
mounting holes are located on the front and rear of
the optional pedestal. The bolt pattern is shown in
Figurez6. The mounting bolts should be 1/2"
diameter or larger. "Red head" or wedge anchor
concrete bolts are usually satisfactory.
If mounting anchor bolts are to be installed prior to
pouring the pad, pay particular attention to the bolt
pattern and the location of the mounting holes with respect to
the center line of the gate hinge. It is critical for the proper
operation of the Arm that the center line of the output shaft of
the RSX4000 operator be located exactly as shown on the bolt
pattern drawing, Figure 6.
ALTERNATE 4 X 4 POST MOUNT
The RSX4000 operator offers an alternative to the optional pedestal
kit for mounting installation. A standard architectural 4 x 4 x 1/8 wall
steel tube may be substituted for the pedestal and installed in a similar
manner to a fence post: Dig a hole of proper diameter (approximately
12") and suitable depth per local codes, and set the 4ZxZ4 post in
concrete. Make sure the post is plumb and level. The top of the post
should be cut off clean and square and should extend at least 18"
above grade. Two 13/32 diameter holes will need to be drilled on each
side of the 4 x 4 tube. Center each pair of holes on the face of the post
installation. ALWAYS
FOLLOW LOCAL BUILDING
CODES.
If no suitable concrete base
exists, a pad must be poured. See
Figurez6 for plans for this pad. If
the location of the operator is
such that vehicles have the
potential of hitting the operator,
consideration should be given to
installation of protective posts in
front of the operator.
106506
Figure 6: Operator Footprint