Table of Contents

Advertisement

12
C
: INSTALLING THE OPERATOR
WIRING AND SUGGESTED PLACEMENT OF OPTIONAL NON-CONTACT SENSOR
(PHOTOELECTRIC) SECONDARY ENTRAPMENT PROTECTION DEVICES
RETRO-REFLECTIVE PHOTOELECTRIC WIRING AND SUGGESTED PLACEMENT SHOWN
B
CLOSE PHOTO
ELECTRIC TRANSCEIVER
A
CLOSE PHOTO
ELECTRIC REFLECTOR
NOTE: THE CLOSE PHOTOELECTRIC
SENSOR IS TO BE MOUNTED NO HIGHER
THAN 27 INCHES OFF THE GROUND AND
NO FURTHER THAN 6 INCHES AWAY FROM
THE GATE MEMBER CENTERLINE WHEN
THE GATE IS FULLY CLOSED.
RETRO-REFLECTIVE
CLOSE PHOTELECTRIC
(See Note 1)
B
REFLECTOR
NC
1
1 - USE A UL RECOGNIZED COMPONENT THAT COMPLIES WITH CURRENT UL 325 REQUIREMENTS,
TERMINAL NUMBERS ABOVE REPRESENT MODEL E3K, WIRING FOR OTHERS SIMILAR
2 - SELECT TERMINAL BASED ON FUNCTION DESIRED, SEE TERMINAL STRIP REFERENCE CHART
C
TRANSCEIVER
POWER
NO
COM
NO
IN
NC
2
3
4
5
6
~
~
1 2 3
A
113498
OVERHEAD VIEW
RETRO-REFLECTIVE
OPEN PHOTELECTRIC
(See Note 1)
TRANSCEIVER
REFLECTOR
POWER
NO
COM NO
IN
4
5
6 ~ ~
C
OPEN PHOTO
ELECTRIC TRANSCEIVER
ENTRAPMENT ZONE
B
OUTSIDE
INSIDE
OPERATOR
TERMINAL
STRIP
16
COMMON
OPEN
12
EDGE
Note 2
11
REVERSE
CLOSE
10
PHOTO
2
24 VAC
1
24 VAC
113497
D
OPEN PHOTO
ELECTRIC REFLECTOR
OPENING
C
D
113499