M38BV-ST B-Vented Fireplace

Wiring

Gas Control and Pilot Wiring
Honeywell (Q3450)
Pilot Assembly
Pilot Electrical
Harness Connector
Honeywell Gas
Control (SV9501M)
Gas Control
Connector
Fan Plug
Receptacle
Grnd Screw
Limit
Wall
Switch
Switch
Figure 5. Wiring for the M38BV-ST-I with Honeywell gas control and
Fans
The M38BV-ST is equipped with 4 fans for circulating heat into
the living space. Installations in Canada must be in accordance
with CSA C22.1 Canadian Electrical Code Part 1 and/or Local
Codes.
Installations in the USA must be in accordance with local codes or,
in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70-1987.
NOTE:
If any of the original wire supplied with the
appliance is replaced, it must be replaced with the
same type, or its equivalent.
L1-WH
G
L2-BLK
Quick Connect
plug to motor
Figure 6a. Wiring for fans.
Page 6
Installation
M38BV-ST-I
Junction Box Cover
Fuse
Junction Box
Black
115VAC
24VAC
Green
40 VA
Transformer
pilot.
Fan motors
115/1/60 Supply
G
L1 L2
Figure 6b. Wiring schematic for fans.
Installing the Log Set
The M38BV-ST is supplied with five (5) fibre logs. To install, simply
place log "A's" rectangular shaped extension into the log mounting
slot located on rear wall of the burner assembly. Place log "B" onto
White
front log slots of the burner assembly. Place log "C" and log "D" onto
the mating positions as shown in Figure 7a below. When log set is
installed it should look like Figure 7b.
Log 'D'
Figure 7a. Log Installation - Step 1.
Figure 7b. Log Installation - Step 2.
If logs are not placed properly, excessive
sooting will result.
Log 'C'
Log 'B'
Log 'A'
Log 'E'
WARNING
:
XG0400 05/00