Operations - Canon PC400 Service Manual

Hide thumbs Also See for PC400:
Table of Contents

Advertisement

CHPTER 4 IMAGE FORMATION SYSTEM

2. Operations

a.
HVPDC=1, HVPHO=1 (copying)
DC bias control circuit set to '-625 V'.
Transformer T106 generates 'DC bias'.
HVPAC=1
Oscillation control circuit goes ON.
Transformer T103 generates AC bias
b.
HVPDC=1, HVPHO=0 (document not exposed)
DC bias control circuit set to '-240 V'.
Transformer T106 generates DC bias.
HVPAC=1
Oscillation control circuit goes ON.
Transformer T103 generates AC bias.
c.
HVPDC=0, HVPHO=0 (standby)
DC bias control circuit goes OFF.
Transformer T106 DC bias goes OFF.
HVPAC=0
Oscillation control circuit goes OFF.
Transformer T103 goes OFF.
4-4
COPYRIGHT © 1998 CANON INC.
CANON PC400/420/430,FC200/220 REV.0 JAN.1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
Primary charging
(DC bias + AC bias) goes ON.
Primary charging
(DC bias + AC bias) goes ON.
Primary charging
(DC bias + AC bias) goes OFF.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc420Pc430Fc200Fc220

Table of Contents