Troubleshooting Malfunctions; (Self Diagnosis; Pc400/Fc200) - Canon PC400 Service Manual

Hide thumbs Also See for PC400:
Table of Contents

Advertisement

CHAPTER 10 TROUBLESHOOTING
IV. TROUBLESHOOTING MALFUNCTIONS
A. Troubleshooting Malfunctions
1.

(self diagnosis; PC400/FC200)

Cause
2. E0
Cause
Thermistor (TH1)
DC controller/DC
power supply PCB
Fixing assembly
10-24
COPYRIGHT © 1998 CANON INC.
Step
Checks
1
Switch the copier ON.
Does the Jam indicator remain
On for about 0.5 sec, and does
the copier go OFF automatically
thereafter?
Step
Checks
1
Set the meter to the '12VDC'
range, and wait until the fixing
heater is sufficiently cool.
Measure the voltage between
J603-1 (+) and J603-2 (-).
Is it about 3.2 V or more?
2
Does the fixing heater operate
normally?
3
Switch the copier ON, and make
a copy.
Measure the voltage between
J603-1 and J603-2 once again.
Is the voltage lower than that
measured in step 1?
CANON PC400/420/430,FC200/220 REV.0 JAN.1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
YES/NO
Remedies
YES
See 'E00'.
NO
See the discussions on
'E2', 'E6', and 'E9'.
YES/NO
Remedies
NO
Check the wiring from the
DC controller/DC power
supply PCB to the ther-
mistor (TH1); if normal,
replace the fixing assem-
bly.
NO
See "The fixing heater fails
to operate."
YES
Replace the DC controller/
DC power supply PCB.
NO
Check the wiring from the
DC controller/DC power
supply PCB to the ther-
mistor (TH1); if normal,
replace the fixing assem-
bly.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pc420Pc430Fc200Fc220

Table of Contents