Brother MFC-9320CW Service Manual page 519

Color fax/mfc
Hide thumbs Also See for MFC-9320CW:
Table of Contents

Advertisement

- Selector 7: Switching between pulse and tone dialing, by the function switch
This selector determines whether or not the dialing mode can be switched between the pulse (DP)
and tone (PB) dialing by using the function switch.
- Selector 8: Default dialing mode, pulse (DP) or tone (PB) dialing
This selector sets the default dialing mode (pulse dialing or tone dialing) which can be changed by
the function switch. If the user switches it with the function switch when selector 7 is set to "0," the
setting specified by this selector will also be switched automatically.
WSW02 (Tone signal setting)
Selector No.
1
Tone signal transmission time length
2
3
Min. pause in tone dialing
4
5
Attenuator for pseudo ring backtone
|
to the line (selectable in the range of
8
0-15 dB, in 1 dB increments)
- Selectors 1 through 4: Tone signal transmission time length and Min. pause in tone dialing
These selectors set the tone signal transmission time length and minimum pause in tone dialing.
(Example: If "1," "2," "3," "4," and "5" are dialed.)
- Selectors 5 through 8: Attenuator for pseudo ring backtone to the line
These selectors are used to adjust the sound volume of a ring backtone in the F/T mode, an on-hold
sound, or a beep generated as a signal during remote control operation or at the start of ICM recording.
The larger the value specified by these selectors, the greater the attenuation.
Function
App.1-5
Setting and Specifications
No. 1 2
0 0: 70 ms
0 1: 80 ms
1 0: 90 ms
1 1: 100 ms
No. 3 4
0 0: 70 ms
0 1: 80 ms
1 0: 90 ms
1 1: 140 ms
0: 0 dB 1: 8 dB
0: 0 dB 1: 4 dB
0: 0 dB 1: 2 dB
0: 0 dB 1: 1 dB