8
Commissioning
.03
● Check the machine, especially the electrical leads, for any damage.
● Have skilled personnel check if the machine can be operated with the available mains vol-
tage.
8
Switching the machine on/off
.04
● Switch the machine on (see Chapter 7.01, On/off switch).
8
Machine drive home position
.05
● Press and hold buttons "A+" and "B+" and switch machine On.
● The control unit will carry out an automatic reset.
● Switch machine on.
● Press button "P" (parameter 47 is displayed).
● Press button "S"; parameter value must be 62.
● Enter the value manually via +/- if required.
● Deactivate input mode by pressing "S".
Before commissioning the machine, clean it thoroughly, fi ll the oil pan with oil
and adjust the oil level, see Chapter 10 Care and Maintenance!
Do not operate the machine if there is any discrepancy.
The machine may only be connected to an earthed socket!
Have home position of the machine drive verifi ed by certifi ed technicians before
fi rst commissioning! Have settings carried out my technicians where required
(see chapter 8.05)
Installation and commissioning
23