6
Installation
Prime Trap by
pouring 300ml of
water into flue spigot
Front Panel and
Control Box
removed for clarity
Condensate Trap Connection
(elbow supplied)
Locating Lug
Case Front Panel
Securing Screws
38
EcoBlue Advance Combi
Fig. 23
Case Front
Panel
6.2.2

Connecting the Condensate Drain

1. Remove the blanking cap, and using the elbow supplied,
connect the condensate drain pipework to the boiler condensate
trap outlet pipe.
Ensure the discharge of condensate complies with any
national or local regulations in force (see British Gas "Guidance
Notes for the Installation of Domestic Gas Condensing Boilers" &
HHIC recommendations).
2. The elbow will accept 21.5mm (3/4in) plastic overflow pipe
which should generally discharge internally into the household
drainage system. If this is not possible, discharge into an outside
drain is acceptable. See section 5.3.5 for further details.
3. The boiler condensate trap should be primed by pouring
approximately 300ml of water into the flue spigot. Do not allow
any water to fall into the air inlet.
6.3

Preparation

6.3.1

Panel Removal

1. Remove the securing screws from the bottom of the case front
panel.
2. Lift the panel slightly to disengage it from the locating lugs on
top of the case and remove it.