Connecting The Condensate Drain; Air Supply/Flue Gas Connections; Connecting The Flue/Chimney - Baxi Assure Combi 36 LPG Installation And Service Manual

High efficiency wall hung condensing gas boiler
Hide thumbs Also See for Assure Combi 36 LPG:
Table of Contents

Advertisement

6 Installation
Fig.30
Pour 300ml of water into flue spigot
6.3

Air supply/flue gas connections

Fig.31
Telescopic flue
1
2
Fig.32
Flue dimension X
X
40
6. The pipework must be clipped at suitable intervals to support it, com­
6.2.2
1. Remove the blanking cap, and using the straight rubber coupling
2. The straight rubber coupling will accept 21.5mm (
PN-0000602
6.3.1
HORIZONTAL TELESCOPIC FLUE (concentric 60/100)
1
2
3
There are two telescopic sections, the terminal assembly and the connec­
3
tion assembly, a roll of sealing tape and two self tapping screws. A 93° el­
bow is also supplied.
The two sections can be adjusted to provide a length between 315mm and
500mm when measured from the flue elbow (there is 40mm engagement
PN-0000462
into the elbow).
1. Locate the flue elbow on the adaptor at the top of the boiler. Set the
2. Measure the distance from the outside wall face to the elbow. This
3. If the distance from the flue elbow to the outside face of the wall is
4. In instances where the dimension " X" is between 250mm and
X
PN-0000463
mencing as close to the boiler as possible.

Connecting the condensate drain

supplied, connect the condensate drain pipework to the boiler con­
densate trap outlet pipe.
See
Ensure the discharge of condensate complies with any national or
local regulations in force (see HHIC recommendations).
See
Condensate drain, page 30.
flow pipe which should generally discharge internally into the house­
hold drainage system. If this is not possible, discharge into an out­
side drain is acceptable.
Important
The boiler condensate trap should be primed by pouring approxi­
mately 300ml of water into the flue spigot. Do not allow any water
to fall into the air inlet.

Connecting the flue/chimney

315mm to 500mm
Connection assembly
Terminal assembly
elbow to the required orientation.
Important
The flue elbow is angled at 93° to ensure a fall back to the boiler.
dimension will be known as " X" .
less than 250mm the connection assembly can be discarded and
the terminal assembly fitted directly into the elbow.
315mm it will be necessary to shorten the terminal assembly by
careful cutting to accommodate walls of these thicknesses.
3
/
in) plastic over­
4