IMPORTANT NOTE: This document
will assist in the correct installation of
the various flue & chimney systems
described within. However, it is the
responsibility of the installer/Gas Safe
registered commissioning engineer to
ensure that the flue & chimney system
is fitted safely and in compliance with
the relevant standards and practices in
force in the country of installation.
Please leave these instructions with the
Installation & Servicing Instructions.
© Baxi Heating UK Ltd 2011
5.3.9

Flue/Chimney Lengths

1. The standard horizontal telescopic flue kit allows for lengths
between 315mm and 500mm from elbow to terminal without the
need for cutting (Fig. 11). Extensions of 250mm, 500mm & 1m
are available.
The maximum permissible equivalent flue length is:
10 metres (60/100 system - vertical & horizontal)
20 metres (80/125 system - vertical & horizontal)
15 metres (80/80 twin pipe)
8 metres (60/100 system - vertical connected to ridge
5.3.10

Flue/Chimney Trim

1. The flexible flue trims supplied can be fitted on the outer and
inner faces of the wall of installation.
5.3.11

Terminal Guard

1. When codes of practice dictate the use of terminal guards
(Fig. 12) 'Multifit' accessory part no. 720627901 can be used
(NOTE: This is not compatible with Flue Deflector referred to
below).
2. There must be a clearance of at least 50mm between any
part of the terminal and the guard.
3. When ordering a terminal guard, quote the appliance name
and model number.
4. The flue terminal guard should be positioned centrally over
the terminal and fixed as illustrated.
5.3.12

Flue/Chimney Deflector

1. Push the flue deflector over the terminal end. It may point
upwards as shown, or up to 45° either way from vertical. Secure
the deflector to the terminal with screws provided (Fig. 13).
5.3.13

Flue/Chimney Accessories

For full details of Flue Accessories (elbows, extensions,
clamps etc.) refer to the Flue Accessories & Fitting Guide
supplied in the literature pack.
5.4

Transport

1. This product should be lifted and handled by two people.
When lifting always keep your back straight and wear protective
equipment where necessary. Carrying and lifting equipment
should be used as required. e.g. when install in a loft.