10
Maintenance
Control Box
removed for clarity
DHW Flow Sensor
('Hall Effect' Sensor)
Fig. 65
Hydraulic
Inlet
Assembly
Diverter
Valve Motor
Multi-pin
Plug
Valve
Assembly
Fig. 66
60
EcoBlue Advance Combi
DHW Flow
Regulator & Filter
Fig. 64
Retaining Clip
Pump, Gas Valve
Assemblies and Pipework
removed for clarity
10.3.18 DHW Flow Regulator & Filter (Fig. 64)
1. Close the cold mains inlet and draw off any residual DHW.
2. Pull off the hall effect sensor. Undo the filter assembly from the
inlet/return manifold.

10.3.19 DHW Flow Sensor ('Hall Effect' Sensor)

(Fig. 65)
1. Pull the sensor off the DHW inlet manifold.
2. Disconnect the plug from the sensor and connect it to the new
component.
3. Fit the new sensor, ensuring it is correctly oriented and fully
engaged over the manifold.
10.3.20 Diverter Valve Motor (Fig. 66)
1. Disconnect the multi-pin plug. Pull off the retaining clip and
remove the motor.
2. The motor can now be replaced,
3. When fitting the new motor it will be necessary to hold the unit
firmly while depressing the valve return spring.
Comp No. 7212138 - 02 (06/14)