Raymarine ST60 Owner's Handbook Manual page 47

Speed instrument
Hide thumbs Also See for ST60:
Table of Contents

Advertisement

Chapter 4: Calibration
At the start of the
from Speed
calibration
sheet 1
Carry out the
return leg of
the second
cal run
At the end
of the return
cal run
press
trip
Speed calibration - sheet 2
7. At the end of the return leg, press the trip key to end the calibration
8. Press the speed and trip keys together, to store the new calibration
outward cal run
press
trip
Alternating
run. At this point:
The text START 2 alternating with the new calibration factor is dis-
played at the top of the screen.
The displayed distance freezes. This value should be very close to
the actual (measured) distance of the calibration run.
factor.
At the end of the
outward cal run
At the start of
the return cal
run press
trip
Press
trip
speed
to store cal factor
Carry out the
outward leg of
the second
cal run
trip
press
Press
speed
to return to
Instrument status display
(Intermediate calibration)
35
D4384-1