6-1-8 Creating Reference Data

Start the setup software.
For subsequent operation, operate the PC
mouse while watching the PC monitor screen.
Information:
It takes approx. 20 minutes to create reference
data.
The following shows the times required for
each item:
Matrix: Approx. 10 minutes
White Balance: Approx. 10 minutes
White Balance Abs: Approx. 30 seconds
Preparation:
1) Point at light box without chart, fi lling the
screen.
2) Prepare the C12 light balancing fi lter (step-
up rings): Attach it during setup.
Procedure:
SETUP MENU screen.
MANUAL ADJUSTMENT PROGRAM for SERVICE STATION
SETUP MENU
Matrix
White Balance
White Balance Abs
2
EXECUTE
1) Choose MATRIX.
2) Click the EXECUTE button.
ATTACH THE FILTER dialog
CHECK
!
Attach The Filter.
OK
1
RETURN
3
3) The ATTACH THE FILTER dialog will
appear during setup. Attach the C12 light
balancing fi lter over the lens of DVD video
camera/recorder, and then click the OK
button.
REMOVE THE FILTER dialog
CHECK
!
Remove The Filter.
OK
4) The REMOVE THE FILTER dialog will
appear during setup.
Remove the C12 light balancing fi lter from
the lens of DVD video camera/recorder, and
then click the OK button.
After that, the ATTACH THE FILTER dialog
and REMOVE THE FILTER dialog may
occasionally appear: Reattach the C12 light
balancing fi lter and remove it each time.
SETUP FINISHED dialog
FINISHED
SETUP FINISHED.
5
OK
5) When setup is complete, the SETUP
FINISHED dialog will appear: Click the OK
button to restore the SETUP MENU screen.
When setup is complete with the C12 light
balancing fi lter attached, remove the C12
light balancing fi lter.