Download Print this page

Toshiba e-STUDIO163 Service Handbook page 40

Hide thumbs Also See for e-STUDIO163:

Advertisement

Notes:
The digit after the hyphen in "Code" of the following table is a sub code.
In "RAM", the SRAM of the board in which the data of each code is stored is indicated. "M"
and "SYS" stands for the MAIN board.
Classi-
Code
fication
200
Devel-
Automatic adjustment of
oper
auto-toner sensor
(Fuser heater ON)
201
Devel-
Correction of auto-toner
oper
sensor
(Fuser heater ON)
205
Devel-
Developer bias DC output
oper
adjustment
210
Charger Main charger grid bias out-
put adjustment
220
Transfer Transfer transformer DC
output adjustment (H)
221
Transfer Transfer transformer DC
output adjustment (C)
222
Transfer Transfer transformer DC
output adjustment (L)
233
Separa-
Separation transformer DC
tion
output adjustment (H)
234
Separa-
Separation transformer DC
tion
output adjustment (C)
235
Separa-
Separation transformer DC
tion
output adjustment (L)
247
Devel-
Relative humidity latest
oper
value
248
Devel-
Drum temperature latest
oper
value
270
Devel-
Temperature latest value
oper
280
Process Forced performing of idling
for toner recycle
286
Laser
Laser power adjustment
e-STUDIO163/166/203/206
ERROR CODE AND SELF-DIAGNOSTIC MODE
Adjustment mode (05)
Func-
Items
tion
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
ALL
2 - 20
07/02
Default
<Accept-
RAM
able
value>
-
-
As the value increases,
the sensor output
increases correspond-
ingly.
The value starts chang-
ing approx. 2 minutes
after this adjustment was
started and is automati-
cally set in the range of
2.35 to 2.45 V.
*
Selection is disable
when developer unit
is not installed.
(Chap. 3.1)
141
M
Corrects the control
<0-255>
value of the auto-toner
sensor setup in 05-200.
*
Selection is disable
when developer unit
is not installed.
135
M
As the value increases,
<0-255>
the transformer output
increases correspond-
75
M
ingly. Remove the devel-
<0-255>
oper unit and install the
117
M
adjustment jig to make
<0-255>
adjustment.
128
M
(Chap. 3.6)
<0-255>
101
M
<0-255>
65
M
<0-255>
65
M
<0-255>
47
M
<0-255>
50
M
Displaying of the relative
<0-100>
humidity latest value.
25
M
Displaying of the drum
<0-100>
temperature latest value.
25
M
Displaying of the temper-
<0-50>
ature latest value.
-
M
Perfom this adjustment
before the replacement
of the developer mate-
rial.(The toner is forcibly
removed from the
cleaner.)
60
M
When the value
<0-255>
increases, the laser out-
put increases corre-
spondingly.
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Proce-
Contents
dure
17
3
3
3
3
3
3
3
3
3
2
2
2
6
3

Hide quick links: