Download Print this page

Toshiba e-STUDIO163 Service Handbook page 100

Hide thumbs Also See for e-STUDIO163:

Advertisement

[G] Bottom margin
<Procedure>
While pressing [0] and [5] simultaneously, turn the power ON. Æ (Adjustment Mode)
(1)
Press [4] Æ [INTERRUPT] Æ [PAPER FEED] (Select from 0: bypass, 1: drawer or 2: PFU.) Æ
(2)
[START] (A solid black pattern (whole area) is printed out. Print out 2 sheets in A3/LD size.).
(3)
Place the paper printed out in step (2) to cover the whole area of the original glass.
(4)
Press [0] and [9] simultaneously to enter the normal mode.
(5)
Make a copy at the mode of A3/LD, 100%, Text/Photo and standard drawer of the equipment.
(6)
Press [0] and [5] simultaneously to enter the adjustment mode.
(7)
Measure the blank area G at the trailing edge of the copied image.
(8)
Check if the blank area G is within the range of 2±1.0 mm.
(9)
If not, use the following procedure to change values and repeat the steps (4) to (8) above.
(Adjustment Mode) Æ (Key in the code [433]) Æ [START]
Æ (Key in a value (acceptable values: 0 to 255))
Æ Press the [INTERRUPT] button (stored in memory).Æ ("AJ" is displayed.)
*The larger the adjustment value is, the wider the blank area at the trailing edge becomes
(approx. 0.04 mm/step).
e-STUDIO163/166/203/206
ADJUSTMENT
Feeding direction
G
Fig. 3-14
© 2005 - 2008 TOSHIBA TEC CORPORATION All rights reserved
3 - 18
06/04

Hide quick links: