DHW with electric power

This function makes it possible to deactivate DHW heating using an integrated
instantaneous heating water heater that may be installed in the unit (e.g. if the
water is subsequently heated by an on-site instantaneous water heater).
The instantaneous heating water heater then only affects the heating circuit.
Access
&
"Device settings"
&
"Programming"
&
"Electric heater"
&
"DHW with electric power"
("YES"/"NO")
Maximum flow temperature
This determines the maximum flow temperature provided by the instantaneous
heating water heater.
Access
&
"Device settings"
&
"Programming"
&
"Electric heater"
&
"Max. flow temp." (1/!)
Heater rod delay
Adjustment of the time during which the electric heating is not switched ON
after changing the operating mode (reduced/standard).
Access
&
"Device settings"
&
"Programming"
&
"Electric heater"
&
"Heater rod delay" (P/Q)
Instantaneous heating water heater control settings
Standard setting
Setting range
Standard setting
Setting range
Standard setting
Setting range
YES
YES/NO
65 °C
5 to 75 °C
0:30 h
0:00 to 5:00 h