Checking The Developer Drive Time; Setting The Fuser Control Temperature - Kyocera FS-6525MFP Service Manual

Hide thumbs Also See for FS-6525MFP:
Table of Contents

Advertisement

Item No.
U157

Checking the developer drive time

Description
Displays the developer drive time for checking a figure, which is used as a reference when cor-
recting the toner control.
Purpose
To check the developer drive time after replacing the developer unit.
Method
1. Press the start key. The developer drive time of each color is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U161

Setting the fuser control temperature

Description
Changes the fuser control temperature.
Purpose
Normally no change is necessary. However, can be used to prevent curling or creasing of paper,
or solve a fuser problem on thick paper.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the setting value using the cursor left/right keys.
Display
T1
T2
T3
T4
T5
T6
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Setting of target temperature of 1st stable
temperature. (Ready)
Setting of target temperature of 2nd stable
temperature. (Standby)
Setting of target temperature at a continuation
copy. (1st copy)
Setting of target temperature at a continuation
copy. (Final)
Setting of target temperature at a continuation
copy. (Addition temperature in every sheet)
Setting of target temperature at a continuation
copy. (Subtraction temperature in every sheet)
Description
1-3-47
2MW/2MX
Setting
Initial
range
setting
120 to 185(°C) 135
120 to 185(°C) 150
130 to 220(°C) 165
130 to 220(°C) 175
1 to 99(°C)
1
1 to 99(°C)
1