FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per-
sonal injury or loss of life.
A. This appliance has a pilot which must
be lighted by hand. When lighting the pi-
lot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around
the appliance area for gas. Be sure to
smell next to the floor because some
gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn
the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don't try to repair it, call a quali-
fied service technician or gas supplier.
Force or attempted repair may result in
a fire or explosion.
D. Do not use this appliance if any part
has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation of
new heater, burning logs will give
off a paper-burning smell. Orange
flame will also be present. Open
damper or window to vent smell.
This will only last a few hours.
126816-01A

OPERATION

www.SuperiorFireplaces.US.com
WARNING:
• If fireplace has glass doors,
never operate this heater with
glass doors closed. If you op-
erate heater with doors closed,
heat buildup inside fireplace
will cause glass to burst. Make
sure there are no obstructions
across openings of fireplace.
• You must operate this heater
with a fireplace screen in place.
Make sure fireplace screen is
closed before running heater.
Note: Home owners generally prefer to operate
their heater with the chimney damper closed.
This will put all the heat into the room. However,
there may be times you will desire the full flames
of the HI heat setting but will find the heat output
excessive. You can open the chimney damper (if
you have one) fully or partially to release some
of the heat.
WARNING: Damper handle
will be hot if heater has been
running.
1. STOP! Read the safety information, col-
umn 1.
2. Make sure equipment shutoff valve is fully
open.
3. Set switch to OFF position.
4. Press in and turn control knob clockwise
to the OFF position (see Figure
57).
Flame
Adjustment
Ignitor
Knob
Selector Switch
Figure 57 - Control Knob, Ignitor Button
and AUTO/OFF/ON Switch
Control Knob in
OFF Position
AUTO
OFF
ON