To Turn Off Gas To Appliance; Manual Lighting Procedure - Desa A Series Owner's Operation And Installation Manual

Unvented (vent-free) propane/lp gas fireplace, variable manuallycontrolled "a" models and thermostaticallycontrolled “c” models with split oak logs
Table of Contents

Advertisement

OPERATING
FIREPLACE
Continued
6.
Continue pressing control knob in.
Press and release ignitor button. This
will light pilot. The pilot is attached to
the front burner. If needed, keep press-
ing ignitor button until pilot lights.
Note : If pilot does not stay lit, con-
tact a qualified service person or gas
supplier for repairs. Until repairs are
made, light pilot with match. To light
pilot with match, see Manual Light-
ing Procedure, column 3.
7. Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob.
Note: If pilot goes out, repeat steps
3 through 7.
• If control knob does not pop out
when released, contact a qualified
service person or gas supplier for
repairs.
8. Slightly depress and turn control
knob couterclockwise
high position. Both burners should
light. Set control knob to either
HIGH or LOW.
Ignitor Electrode
Thermocouple
Pilot Burner
Figure 43 - Pilot
104410
VARIABLE CONTROL
OPERATION
The variable control valve can be set to any
heat setting and flame height desired, by
simply turning the control knob until that
setting is attained. Even the lowest setting
provides realistic flames and glowing em-
bers from two burners. Selecting higher
settings produces greater heat output. This
results in increased heating comfort.
WARNING: Do not operate
heater between locked positions.
CAUTION: Do not try to adjust
heating levels by using the
manual shutoff valve.
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
to the HIGH position.
2. Slightly depress control knob and
to the
turn clockwise
position.
3. Slightly depress control knob and
turn clockwise
position.
Shutting Off Burners Only (pilot
stays lit)
1. Turn control knob clockwise
to the HIGH position.
2. Press in and turn clockwise
to the PILOT position.
OWNER'S MANUAL
1.
2.
3.
Clockwise
to the PILOT
Clockwise
to the OFF
Clockwise
Clockwise
Clockwise
19
MANUAL LIGHTING
PROCEDURE
Follow steps 1 through 5 under Light-
ing Instructions, page 18.
Depress control knob and light pilot
with match.
Keep control knob pressed in for 30
seconds after lighting pilot. After 30
seconds, release control knob. Now
follow step 8, column 1.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C seriesVsgf28pvaVsgf28ptcCsgf28ptc

Table of Contents