Appendix B - H34D-MH Mobile Home
This appliance may be installed as an OEM installa-
tion in a manufactured home (USA only) or mobile
home and must be installed in accordance with the
manufacturer's instructions and the Manufactured
Home Construction and Safety Standard, Title 24
CFR, Part 3280, in the United States or The Mobile
Home Standard, CAN / CSA Z240 MH Series, in
Canada. This appliance is only for use with the
type(s) of gas indicated on the rating plate. A conver-
sion kit is supplied with the appliance.
H34D-MH Mobile Home
The mobile home option is a factory installed on the H34D-MH gas
fireplace, and is for use in a manufactured or mobile home.
The standard H34D or the H34D-I equipped with Hot Surface
Ignition (HSI) are not approved for use in mobile or manufac-
tured homes.
The H34D-MH is rated for:
Natural Gas at 18,000 BTU/H (5.28 Kilowatts) max. input, and
14,000 BTU/H (4.10 Kilowatts) min. input.
Propane at 18,000 BTU/H (5.28 Kilowatts) max. input, and 14,000
BTU/H (4.10 Kilowatts) min. input.
A manufactured home (USA only) or mobile home
OEM installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR,
Part 3280, or when such a standard is not applicable,
the Standard for Fire Safety Criteria for Manufactured
Home Installation Sites and Communities, ANSI/NFPA
501A, in the United States or the Mobile Home Stand-
ard, CAN / CSA Z240 MH Series, in Canada.
Part No. XG0130
Gas Control Valve
The following gas control valve is installed on the H34D-MH.
Pilot Adjustment Screw
Inlet
Pressure
Manifold Pressure
Test Connection
Figure B1. Sit Nova 820 gas valve.
Conversion Kits
The H34D-MH mobile home appliance is field convertible between
Natural Gas (NG) and Propane (LP).
To convert from Natural Gas to Propane order conversion kit #
RCVxxx.
To convert from Propane to Natural Gas order conversion kit #
RCVxxx.
Conversion kits are available for standard H34D conversion between
Natural Gas (NG) and Propane (LP).
H34D Gas Fireplace
Power
Generator
Wall Switch