Unit-Mounted Controller & Remote Thermostats; Programmable Electronic Thermostat (P/N 910140679); Non-Programmable Electronic Thermostat (P/N 910140678) - Daikin IM 1193 Installation & Maintenance Data

Packaged terminal air conditioner 16" x 42" pgan with top-mounted hydronic heat
Table of Contents

Advertisement

Unit-Mounted Controller & Remote
Thermostats
Programmable Electronic Thermostat
(P/N 910140679)
7-Day Programmable, Auto Changeover, Fan Speed
Control, Hardwired
■ 7-Day Programmable
■ Single Stage Heat Pump/Non-Heat Pump Systems
■ Backlit Display
■ Single Stage Heat/Cool Systems
■ Field Calibration
■ Auto Changeover
■ Button Lockout Function
■ Two Speed Fan Control
■ SimpleSet™ Programming
■ Remote Temperature Sensor Capability
■ Title 24 Compliant / No Batteries Required
■ Relay Outputs (minimum voltage drop in thermostat)
■ Ideally Suited for:
– Residential (New Construction/Replacement)
– Light Commercial
Specifications
Electrical rating:
■ 24 VAC (18-30 VAC)
■ 1 amp maximum per terminal
■ 3 amp maximum total load
Temperature control range:
45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C)
System configurations:
1-stage heat, 1-stage cool, heat pump
Timing:
Anti-short Cycle: 5 minutes
Backlight Operation: 10 seconds
Terminations:
C, RH, RC, W, Y, B, O GL, GH, S1, S2
For detailed installation, operation and application refer to
Operation & Application Guide LIAF186
Non-Programmable Electronic Thermostat
(P/N 910140678)
Non-Programmable, Auto Changeover, Fan Speed
Control, Hardwired
■ Single Stage Heat Pump/Non-Heat Pump Systems
■ Backlit Display
■ Single Stage Heat/Cool Systems
■ Field Calibration
■ Auto Changeover
■ Button Lockout Function
■ Two Speed Fan Control
■ Remote Temperature Sensor Capability
■ Title 24 Compliant / No Batteries Required
■ Relay Outputs (minimum voltage drop in thermostat)
■ Ideally Suited for:
– Residential (New Construction/Replacement)
– Light Commercial
Specifications
Electrical rating:
■ 24 VAC (18-30 VAC)
■ 1 amp maximum per terminal
■ 3 amp maximum total load
Temperature control range:
45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C)
System configurations:
1-stage heat, 1-stage cool, heat pump
Timing:
Anti-short Cycle: 5 minutes
Backlight Operation: 10 seconds
Terminations:
C, RH, RC, W, Y, B, O GL, GH, S1, S2
For detailed installation, operation and application refer to
Operation & Application Guide LIAF187
IM 1193 / Page 17 of 32