Vent Information and Diagrams

A. Vent Table Key
The abbreviations listed in this vent table key are used in
the vent diagrams.
Symbol
V
Minimum Vertical Run Length 14 ft.
MIN
V
Maximum Vertical Run Length 50 ft.
MIN
B. Horizontal Venting
Horizontal venting is NOT allowed.
C. Measuring Standards
Vertical measurements listed in the vent diagram (Figure
5.1) were made using the following standard:
• Vertical terminations are measured to top of chimney.
Figure 5.1
Description
EXHAUST COLLAR
INLET AIR COLLAR
V= 14 FT. MINIMUM
50 FT. MAXIMUM
(Factory installed to
stainless steel section)
BLOCK PIPE END WITH
INSULATION OR ANY OTHER
STAINLESS STEEL
REQUIRED (INCLUDED)
COLLAR ATTACHMENT
Heat & Glo • FB-IN, FB-GRAND • 783-908 Rev. J • 2/07
Fire Hazard.
Explosion Risk.
Asphyxiation Risk.
Do NOT connect this gas appliance to a
chimney ue serving a separate solid fuel or
gas burning appliance.
• May impair safe operation of this appliance
or other appliances connected to the ue.
• Vent this appliance directly outside.
• Use separate vent system for this appliance.
ALL vent speci cations MUST be followed.
• This product is tested and listed to these speci cations.
• Appliance performance will suffer if speci cations are not
followed.
TERMINATION
CAP
ADAPTOR
EXHAUST
VENT PIPE
3 INCH COLLAR
WARNING: DO NOT
SEALING MATERIAL
PIPE - 3 FT. MIN.
INLET AIR
VENT PIPE
BRACKET
WARNING
CAUTION
9