Three-Wire Electrical Connection To Receptacle; Center - Kenmore Washer/Dryer Owner's Manual And Installation Instructions

Kenmore washer/dryer user manual
Hide thumbs Also See for Washer/Dryer:
Table of Contents

Advertisement

I. THREE-WIRE
ELECTRICAL
CONNECTION
TO RECEPTACLE
Use a 3-wire power supply cord:
Fire Hazard
Use a new UL approved 30 ampere
power supply cord.
Use a UL approved strain relief.
Disconnect power before making
electrical connections.
Connect neutral wire (white or center
wire) to center terminal (silver).
Ground wire (green or bare wire)
must be connected to green ground
connector.
Connect remaining 2 supply wires
to remaining 2 terminals (gold).
Securely tighten all electrical
connections.
Failure to follow these instructions
can result in death, fire, or electrical
shock.
UU
Thisbladeconnected
Neut_ral
_.._:_,,_j
tothis conductor
Local codes may permit the use of
a U.L.-listed,
120/240-volt
minimum,
30-ampere,
dryer power supply cord
kit (pigtail). Power supply cord should
be type SRD or SRDT and be at least
four feet long. The wires that connect
to the laundry center must end with
ring terminals or spade terminals with
upturned ends.
Do not use an extension cord with
this laundry center.
Do not connect plug end of power
supply cord into a live receptacle
before connecting
power supply cord
to laundry center terminal block.
The power supply cord must have three,
No.-10 copper wires to match a three-
wire receptacle of NEMA Type 10-30R.
Spade terminals
with upturned ends
(OR ring terminals)
Connectwire
with ends
facing you
Ring
terminals
(OR spade
terminals)
3h-inch, U.L.-listed,
strainreliel
Neutralwire
(white)
Three-Wire
Power Supply Cord
Three-wire receptacle
(NEMA TypelO-3OR)
17