4-Wire Connection With Frame-Grounding Conductor - Kenmore Washer/Dryer Owner's Manual And Installation Instructions

Kenmore washer/dryer user manual
Hide thumbs Also See for Washer/Dryer:
Table of Contents

Advertisement

STEP 5. Connect neutr=:dgrounding wire
and the neutral wire (white) of power
supply cord under the center screw of
terminal block.
STEP 6. Connect the other two insulated
wires to outer terminal block screws.
STEP 7. Connect the grounding wire
(green) of the power supply cord to the
external grounding
conductor
screw.
Securely tighten all electrical connections.
STEP 8. Insert tab of te=Tninal block
cover into slot of the laundry center rear
panel. Secure cover with hold-down
screw.
Pn)ceed with Installation
on page 27.
Green wire
of power supply
cord or bare
copper wire
Neutral
grounding wire
(green]yellow)
\
Center silver-
colored terminal
block screw
Neutral wire
(white)
External
ground
connector
3/4-inch,U.L.-listed,
strain relief
4-Wire Connection
with
Frame-Grounding
Conductor