Fall Protection - Genie S-40 Operator's Manual

Hide thumbs Also See for S-40:
Table of Contents

Advertisement

Operator's Manual
OPERATING INSTRUCTIONS
Generator
To operate the generator, move the generator
toggle switch to the generator position. The engine
will continue to run but no drive or platform
functions will operate.
Plug power tools into the power to platform GFCI
outlet.
To resume machine functions, move the generator
toggle switch to the machine functions position. All
functions will operate.
Engine Idle Select (rpm)
Select engine idle (rpm) using the symbols on the
control panel.
Rabbit and foot switch symbol:
foot switch activated high idle
Turtle symbol: low idle
Rabbit symbol: high idle
Check Engine Light (if equipped)
Light on and engine stopped: Tag the machine and
remove from service.
Light on and engine still running: Contact service
personnel within 24 hours.
26
Stopping the Engine
Push in the red Emergency Stop button and turn
the key switch to the off position.

Fall Protection

Personal fall protection equipment (PFPE) is
required when operating this machine.
All PFPE must comply with applicable
governmental regulations, and must be inspected
and used in accordance with the PFPE
manufacturer's instructions.
After Each Use
1 Select a safe parking location—firm level
surface, clear of obstruction and traffic.
2 Retract and lower the boom to the stowed
position.
3 Rotate the turntable so that the boom is between
the non-steer wheels.
4 Turn the key switch to the off position and
remove the key to secure from unauthorized
use.
5 Chock the wheels.
Genie S-40 & Genie S-45
Second Edition • Ninth Printing
Part No. 43645