12
Converting to a different gas type
This appliance is suitable for use with Natural gas or LPG (check the "gas type" sticker attached
to the appliance). To convert from one gas type to another, you need to replace the injectors,
and then adjust the minimum burning setting.
Replacing the injectors
Remove the trivets and burners from the cooktop.
1
Using a spanner, remove the injectors (shown in Figs. 7-8 following) and replace them with ones
2
according to the gas type (see the 'Table for the choice of injectors').
Fix the warning label (supplied with the conversion kit) at the back of the cooker, near the gas
3
inlet connections. This label states that the gas cooktop has been converted for use with LPG/
Natural gas.
Adjusting the minimum burner setting
Follow the instructions, 'Adjusting the minimum burner setting' .
4
Important!
If you are converting the cooker from Natural gas to LPG,remove the gas pressure regulator
before connecting the cooker to the gas supply and replace with the test point adaptor supplied
with the conversion kit.
If you are converting the cooker from LPG to Natural gas, remove the test point adaptor before
connecting the cooker to the gas supply and replace with the gas pressure regulator supplied
with the conversion kit.
Notes:
- The burners are designed so that regulation of primary air is not required.
Fig. 7 Auxiliary and semi-rapid burners
Injector
Injector
Fig. 8 Triple-ring wok burner