5. DIAG. TEST OPERATION

5.3.23 Threshold Manual Fine Adjustment for the Black Mark Sensor

< 1
< 2
Press the [PAUSE] key 25 times.
T H
Press the [FEED] key or [RESTART] key to
fine adjust the threshold for the black
Press the [FEED] key and [RESTART] key
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables a fast
forward.
2. A changed threshold fine adjustment value is stored in memory by pressing the [PAUSE]
key.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
>
D I A G .
V 1 . O A
Press the [FEED] key.
>
P A R A M E T E R
R
E S H O L
D
< R >
mark sensor manually.
at the same time.
S E T
[FEED] key:
1 . 0 V
[RESTART] key: Pressing the [RESTART] key one
Press the [PAUSE] key .
Continued on Section 5.3.24
Threshold Manual Fine Adjustment
for the Feed Gap Sensor.
5-45
EO18-33004
5.3 PARAMETER SETTING MODE
Pressing the [FEED] key one
time is a -1.0V change, up to
0.0V.
time is a +1.0V change, up to
4.0V.