CHILD-PROOF PROTECTION - See Figure 76
1. Press and hold the ON and OFF buttons simultaneously for 3 seconds to enter
childproof mode as shown in this picture.
2. The transmitter will not send a signal again until childproof mode is deactivated
by pressing the ON and OFF buttons simultaneously for 3 seconds to exit child-
proof mode and the Childproof indicator disappears from LCD.
TRANSMITTER THERMAL SHUTDOWN - See Figure 77
1. If transmitter measures a room temperature exceeding 99 degrees Fahrenheit, the
LCD will display "HI" and the transmitter will turn off the appliance.
2. Transmitter will not function until the room temperature has dropped below 99°
Fahrenheit. If transmitter measures a room temperature less than 40° Fahrenheit,
the LCD will display "LO" and NO SIGNAL will be sent to turn on the
appliance.
RECEIVER
- See Figure 78
SLIDE SWITCH
1. ON position: the main burner will ignite and blower will
come on when Blower on Delay Time is reached and fan speed
has been enabled, the flame height is max; otherwise just the
burner will ignite until the slide switch is placed in the OFF or
RS positions.
2. RS position: the system will only operate if the remote receiver
receives a signal from the transmitter.
3. OFF position: the system is off. If fan speed has been enabled
blower will continue to operate until Off Delay Time expires.
The slide switch should be placed in the OFF position
if you will be away for an extended period of time. The
OFF position also functions as a safety device by both turning
the system off and rendering the receiver inoperable.
OPTIONAL 6-HOUR SHUTDOWN
1. The receiver comes preset from the factory with a 6-hour shutdown from its last ON or flame lower operation. This
is done to prevent the appliance from continuing to run if unattended.
2. You may disable this feature if you wish. To disable, change the receiver privacy (DIP) switch #1 ONLY to the OFF
position. Make sure the transmitter privacy (DIP) switches are set the same as the receiver. Follow the instructions
on how to set the privacy (DIP) switch setting.
3. If you disable this feature, your appliance will continue to run unattended.
56D3049
OPERATING INSTRUCTIONS - REMOTE HI/LO WITH BLOWER
Child Proof Protection
Transmitter Thermal
Switch
O N
R S
O F
F
Figure 78 - Receiver
70
° F
Figure 76 -
HI
Figure 77 -
Shutdown
Continued
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

500dvhnv500dvhpv500dvhne500dvhpe500dvhrnv500dvhrpv

Table of Contents