VIVOTEK
8.14 Virtual input
Note: Change virtual input (manual trigger) status.
Method: GET
Syntax:
http://<servername>/cgi-bin/admin/setvi.cgi?vi0=<value>[&vi1=<value>][&vi2=<value>]
[&return=<return page>]
PARAMETER
VALUE
vi<num>
state[(duration)nstate]
Where "state" is 0, 1. "0"
Where "nstate" is next
return
<return page>
Return Code
Description
200
The request is successfully executed.
400
The request cannot be assigned, ex. incorrect parameters.
Examples:
setvi.cgi?vi0=0(10000)1(15000)0(20000)1
setvi.cgi?vi3=0
setvi.cgi?vi=1
503
The resource is unavailable, ex. Virtual input is waiting for next state.
Examples:
setvi.cgi?vi0=0(15000)1
setvi.cgi?vi0=1
Request 2 will not be accepted during the execution time(15 seconds).
172 - User's Manual
(capability.nvi > 0)
means inactive or normal
state while "1" means
active or triggered state.
state after duration.
No multiple duration.
VI index is out of range.
No VI index is specified.
DESCRIPTION
Ex: vi0=1
Setting virtual input 0 to trigger state
Ex: vi0=0(200)1
Setting virtual input 0 to normal state, waiting 200
milliseconds, setting it to trigger state.
Note that when the virtual input is waiting for next
state, it cannot accept new requests.
Redirect to the page <return page> after the request is
completely assigned. The <return page> can be a full
URL path or relative path according the current path.
If you omit this parameter, it will redirect to an empty
page.