4.5.2 Default setting for the programme.
Activate the programme and set defaults.
4.5.3 RF calibration
1. Apply 4 V using a stabilised power supply and turn on the handset (phone).
2. Start "RF calibration & check" on SPST and click "Cal".
3. When initialisation is complete, the following message appears. Lower the stabilised power supply voltage to 3.7 V and click "OK".
CONFIDENTIAL
1) A connected COM port
appears.
2) Set the GPIB No.
3) Select the test instrument.
4) Set the GPIB address.
5) Set the "Cable Offset" values.
For cables with connector
QCNWK0138AFZZ/
QCNWK0136AFZZ, set the
values as follows:
GSM 900: 0.60
DCS 1800: 0.95
PCS 1900: 0.96
6) Auto Dial Setting
When the Auto Dial check
box is checked, an entered
number is automatically
dialled for performance
check.
7) Number Setting
Enter a number for Auto Dial.
Figure 40
Figure 41
2 – 20