3. To adjust the Level, press the softkey labeled Go to Level (see "Setting
the Level").
4. To capture an image, squeeze and release the trigger once.
5. To exit the manual level and span adjustment, squeeze and release the
trigger quickly twice in order to return to live view.
The Imager remains at this Span until it is manually adjusted again, or the
Imager returns to auto mode.

Setting IR-Fusion and PIP

®
IR-Fusion
, only from Fluke, allows the user to utilize various modes that
combine a thermal image with a visual (visible light) image. The Imager is set
to one of three different levels of blending. In addition to setting the visual to
thermal blending, the IR-Fusion
image display and a Picture-In-Picture (PIP) display. To set the IR-Fusion
level and PIP display:
1. Press a until IRFusion appears over d.
2. Press the softkey labeled IRFusion to reveal the IR-Fusion
3. Press the softkey labeled Up or Down to move between the six
®
IR-Fusion
settings. The top three settings select a PIP display. The
bottom three settings have full screen IR with different levels of visible
blending.
4. Press the softkey labeled Done when finished.
5. Wait for main menu to disappear or quickly squeeze and release the
trigger twice in order to return to live view.

Reviewing and Deleting Stored Images

To enter the Review mode and view stored images on the SD memory card:
1. Press a until Review appears over c.
2. Press the softkey labeled Review to bring up the thumbnail review of
images stored in memory.
3. Press the softkey labeled Left and Right Arrows to navigate through
the thumbnail images.
®